Page 130 InterReach Fusion Wideband Installation, Operation, and Reference Manual
© 2013 TE Connectivity Ltd D-620616-0-20 Rev H TECP-77-044 Issue 7 May 2013
CAUTION! ObserveallFiberPortSafetyPrecautionslistedin“SafetyPrecautions”onpage109.
PreparingtheFiberCables
1 Confirmthattheiropticallossdoesnotexceed3dBopticalbudget.RLislessthan‐60dB.
2 I
ffiberdistributionpanelsareused,confirmthatthetotalopticallossoffibercable,fromthe
MainHubthroughdistributionpanelsandpatchcordstotheExpansionHub,doesnotexceed
theopticalbudget.
3 Makesurethefibercable’s
connectorsareSC/APC(angle‐polished).Usinganyother
connectortypewillresultindegradedsystemperformanceandmaydamagethe
equipment.(YoucanuseanSC/APCpigtailifthefibercable’sconnectorsarenotSC/APC,
referto“FusionWidebandSplicingofF
iberandPigtail”onpage145,orreplacethe
connectors.)
ConnectingtheFiberCables
Thefibercableislabeledwitheither1or2,oriscolor‐coded.Forproperconnectionbetweenthe
MainHubportsandtheExpansionHubports,refertothenumberingorcolor‐codedconnections
yourecordedwheninstallingtheMainHub(s).
Ifth
eFiberJumperIsLabeledwith1or2
1 Connect2toDOWNLINKontheExpansionHub.
The
DL STATUSLEDshouldturngreenassoonasyouconnectthefiber.Ifitdoesnot,thereisa
downlinkproblem.Makesureyouareconnectingthecorrectcabletotheport.
2 Connect
1toUPLINKonExpansionHub.
The
UL STATUSLEDturnsgreenonthefirstMainHubcommunication.Itmaytakeupto20
secondstoestablishcommunication.
TheExpansionHub’s
E-HUB STATUSLEDturnsgreenwhentheMainHubsendsitthefrequency
bandcommand.
3 If
theUL STATUSandE-HUB STATUSLEDsdonotturngreen/green,checktheMainHubLEDs;
seeStep2inTable87onpage126.
ConnectingtheFiberCablestotheExpansionHub