OptionalConnectiontoDCPowerSource
Thisisanoptionalconnectionmethodusingringtonguelugsinsteadofthecompressionlugsthat
arepre‐mountedontheterminalblock.Usewireselectioninstructionspreviouslyexplained.
CAUTION! Beforeconnectingpowerwires,besurethepowersourceisshutoff,andthepowerswitchof
thehubsareintheOFFposition.Connectthegroundwiresbeforeconnectingthepowerwires.
1 Removetheexistingcompressionlugsbyfirstremovingthemountingscrewsasshownin
Figure30.
Figure30.
Locations of the Compression Lug and Mounting Screw
2 ConnectthesafetygroundwireaspreviouslyexplainedandshowninFigure31.Use14AWG
minimumwirewitha#8‐32studsize
ringlugasshowninFigure32onpage125.
Figure31
.Grounding Wire Connection