User's Manual Part 2
Table Of Contents
- Replacing Fusion Wideband Components
- Maintenance, Troubleshooting, and Technical Assistance
- Appendix A: Cables and Connectors
- Appendix B: Compliance
- Appendix C: Faults, Warnings, Status Tables for Fusion, Fusion Wideband, Fusion SingleStar
- Appendix D: Contacting TE Connectivity
Installing Fusion Wideband
Page 116 InterReach Fusion Wideband Installation, Operation, and Reference Manual
© 2013 TE Connectivity Ltd D-620616-0-20 Rev H • TECP-77-044 Issue 7 • May 2013
Usethescrewsprovidedtofastenthecablemanagertotherack,immediatelyaboveorbelowthe
MainHub.
NOTE: Themaximumweightthebracketcanholdis22.5kg(50lbs).
NOTE: Thebra
cketisdesignedtoaccommodate aFusionWidebandMainHub(12lbs.)oranExpansion
Hub(14.5lbs.).
NOTE: Thewallmo
untbracketshouldbesecurelymountedtowall,usingthefourkeyslotmounting
holesonthebracket.
NOTE: Thera
ck‐mountingbracketsontheFusionWidebandMainHubmustbemovedtotherecessed
mountingposition(shownin Figure22)toallowfo
rtherequired76mm(3in.)rearclearance.
1 Attachthewallbracket(PN4712)towalltheusing#10PanHeadwoodscrews,1‐1/2”
minimumlengthformountinginwoodstudsor3/4“thickplywood.Thebracketmustbe
positionedsothattheHubwillbeinahorizontalpositionwhenitisinstalled.(Referto
Figure22.)
NOTE: Ifwall studspacingof16”is notavailable, pre‐install3/4 ” plywood to thewall.Youcanthen
attachthebrackettotheplywoodusingthewoodscrews.
Figure22.Bracket Detail For Wall Mount Rack (PN 4712)
2 RemovebothoftherackmountingbracketsfromtheHub.
3 Reattacheachoftherackmounting
bracketstotherecessedwallmountposition.
4 InstalltheHubintherackusingt
herackmountingscrews.
InstallinganOptionalCableManagerintheRack
InstallingaMainHubUsingthe12”Wall‐MountedRack(PN4712)