User's Manual Part 1
Table Of Contents
- Preface
- InterReach Fusion Wideband System Description
- System Overview
- System Hardware Description
- System OA&M Capabilities Overview
- System Connectivity
- System Operation
- System Specifications
- RF End-to-End Performance
- 2100/1800 RAU (FSN-W1-2118-1)
- 2100 HP/1800 HP (FSN-W1-2118-1-HP)
- 2100 High Power RAU (FSN-W1-21HP-1)
- 1900/AWS RAU (FSN-W1-1921-1)
- 800/850/1900 RAU (FSN-W2-808519-1)
- 700/AWS RAU (FSN-W2-7021-1)
- 700/700 (Upper C) MIMO RAU (FSN-W2-7575-1)
- 700/700 (Lower ABC) MIMO RAU (FSN-W2-7070-1)
- 700 ABC/AWS HP/AWS HP RAU (FSN-W4-702121-1-HP)
- 700 UC/AWS HP/AWS HP RAU (FSN-W4-752121-1-HP)
- 850/1900 HP/AWS HP RAU (FSN-W5-851921-1-HP)
- 2500/2500 RAU (FSN-2500-2-WMAX)
- 2600/2600 RAU (FSN-W3-2626-1)
- Fusion Wideband Main Hub
- Fusion Wideband Expansion Hub
- Remote Access Unit
- Designing a Fusion Wideband Solution
- Overview
- Downlink RSSI Design Goal
- Maximum Output Power per Carrier
- 700/AWS RAU (FSN-W2-7021-1)
- 700 MHz (Upper C) MIMO RAU (FSN-W2-7575-1)
- 700 MHz (Lower ABC) MIMO RAU (FSN-W2-7070-1)
- 700 ABC/AWS HP/AWS HP RAU (FSN-W4-702121-1-HP)
- 700 UC/AWS HP/AWS HP RAU (FSN-W4-752121-1-HP)
- 800/850/1900 RAU (FSN-W2-808519-1)
- 850/1900 HP/AWS HP RAU (FSN-W5-851921-1-HP)
- 1900/AWS RAU (FSN-W1-1921-1)
- 2100/1800 RAU (FSN-W1-2118-1)
- 2100 HP/1800 HP RAU (FSN-W1-2118-1-HP)
- 2100 High Power RAU (FSN-W1-21HP-1)
- 2500/2500 WiMAX RAU (FSN-2500-2-WMAX)
- 2600 MHz MIMO RAU (FSN-W3-2626-1)
- Designing for Capacity Growth
- System Gain
- Estimating RF Coverage
- Link Budget Analysis
- Optical Power Budget
- Connecting a Main Hub to a Base Station
- Installing Fusion Wideband
Fusion Wideband Expansion Hub
Page 44 InterReach Fusion Wideband Installation, Operation, and Reference Manual
© 2013 TE Connectivity Ltd D-620616-0-20 Rev H • TECP-77-044 Issue 7 • May 2013
ExpansionHubFrontPanel
Figure15.Expansion Hub Front Panel
Ref # Description
1 One port LED and connector pair for 8 ports (labeled Port n, wher
e n = 1 - 8):
• One port LED per type F connector p
ort for link status and downstream RAU status (8 pair total).
• Eight CATV cable, type F connectors
2 One pair of unit status LEDs
• One LED for unit power status (labeled POWER)
•
One LED for unit status (labeled E-HUB STATUS)
3 One set of fiber status LEDs
• One LED for fiber uplink status (labeled UL STATUS)
•
One LED for fiber downlink status (labeled DL STATUS)
4 One fiber optic port which has two connectors
• One standard female SC/APC connector for MMF/SMF output (labeled Uplink)
• One standard female SC/APC connector for MMF/SMF input (labeled Downlink)
5 One 9-pin D-sub male connector for TE factory testing
(labeled Console)
6 One RJ-45 female connector for system communication and
diagnostics using a PC/laptop with direct connect or
using a LAN switch (labeled Admin/Lan)
7 Power Switch
1
Unit is not shown to scale.
Port 1
CONSOLE
Port 2 Port 3 Port 4 Port 5 Port 6 Port 7 Port 8
UPLINK
DOWNLINK
InterReach Fusion
Expansion Hub
ADMIN/LAN
POWER
EH STATUS
DL STATUS
UL STATUS
Port 1
2 3 4
5
6
7