Page 30 InterReach Fusion Wideband Installation, Operation, and Reference Manual
© 2013 TE Connectivity Ltd D-620616-0-20 Rev H TECP-77-044 Issue 7 May 2013
FUSIONWIDEBANDMAINHUBOVERVIEW
TheFusionWidebandMainHub(showninFigure8)distributesuptothreeindividual(Band1,2,
and3)downlinkRFsignalsfromabasestation,repeater,orFlexWave
Focussystemtouptofour
ExpansionHubs,whichinturndistributethesignalstoupto32RemoteAccessUnits.TheMain
HubalsocombinesuplinksignalsfromtheassociatedExpansionHubs.
FusionWidebandisamulti‐bandsy
stem.OneRFsource(Band1orRF1)goestothe60MHzband
andtheotherRFsource(Band2orRF2)goestothe75MHzband.Band3(orRF3)goestoa25
MHzsub‐bandofthe60MHzbandandisfunctionalonlywiththe800/850/1900,700/AWS,
700/700(UpperC)MIMO,700/700(LowerABC)MIMO,700ABC/AWSHP/AWSHP,700
UC/AWSHP/AWSHP,and850/1900HP/AWSHPRAU.Thesysteminstallsina19"equipment
rackandisusuallyco‐locatedwiththeRFsourceinatelecommunicationscloset.
Figure8.
Main Hub in a Fusion Wideband System
Figure9onpage31showsadetailedviewofthemajorRFandopticalfunctionalblocksofthe
MainHub.
TheFusionWidebandOnePortMainH
ub(PNs:FSN‐W1‐MH‐2‐1P,FSN‐W2‐MH‐3‐1P,
FSN‐W3‐MH‐1P,FSN‐W4‐MH‐1P,andFSN‐W5‐MH‐1P)configurationisacostreducedversionof
theFusionWidebandMainHubandsupportsonlyoneExpansionHub(upto8RAUs).
Downlink Path: The Main Hub receives up to 3 individual (Band1, 2, or 3) downlink RF signals from a base station, repeater,
or FlexWave Focus system using 50 Ohm coaxial cable. It converts the signals to IF then to optical and sends them to up to
four Expansion Hubs using fiber optic cable.
The Main Hub also sends OA&M communication to the Expansion Hubs using the fiber optic cable. The Expansion Hubs,
in turn, communicate the OA&M information to the RAUs using CATV cable.
Uplink Path: The Main Hub receives uplink optical signals from up to four Expansion Hubs using fiber optic cables. It converts
the signals to IF then to RF and sends them to the respective Band1, 2, or 3 base station, repeater, or FlexWave Focus system
using 50 Ohm coaxial cable.
The Main Hub also receives status information from the Expansion Hubs and all RAUs using the fiber optic cable.
RF1, 2, and 3
Downlink to Main Hub
Uplink from Main Hub
RF1, 2, and 3
Downlink to Main Hub
Uplink from Main Hub
Fusion Wideband
Main Hub
Fusion Wideband
Main Hub
RAU