User's Manual Part 1

Table Of Contents
System Specifications
InterReach Fusion Wideband Installation, Operation, and Reference Manual Page 17
D-620616-0-20 Rev H • TECP-77-044 Issue 7 May 2013 © 2013 TE Connectivity Ltd.
SYSTEMSPECIFICATIONS
NOTE: Note: The Fusion Wideband Main Hub’s typical power consumption assumes that the CATV
RG59 cable length is no more than 130 meters, the RG6 cable length is no more than 140
meters,andRG11cablelengthisnomore than235metersusingCommScope2065V,2279V,and
2293Kcables.
Table1. PhysicalSpecifications
Parameter Main Hub Expansion Hub Remote Access Unit
IF/RF Connectors 4-type “N” female
(a)
(50 Ohm),
1 Downlink/Uplink pair per
ba
nd
8-type “F”, female
(CATV 75 Ohm)
One F, female (CATV -75 Ohm)
One N, female
(b)
(antenna-50 Ohm)
External Alarm Connector
(contact source)
One, 9-pin D-sub, female One, 9-pin D-sub, female
ADMIN/LAN Interface
Connectors
One RJ-45, female
One 9-pin D-sub, male for
o
ptional modem
One RJ-45, female
One 9-pin D-sub, male
Fiber Connectors
(c)
4 pair, SC/APC
(d)
One pair, SC/APC
LED Alarm and Status
Indicators
Unit Status (One pair):
•Power
Main Hub Status
Downstream Unit Status
(One per fiber port):
Expansion Hub/RAU
Unit Status (One pair):
•Power
Expansion Hub Status
Fiber Link Status (One pair):
•DL Status
•U
L Status
Port Status:
One per F connector port
•L
ink/RAU
Unit Status (One pair):
•Link
•A
larm
Power (AC Option) Rating: 100–240V AC, 1A,
50–60 Hz
Operating Range: 90–132V
AC/170
-250V
AC auto-ranging
Rating: 100–240V AC, 6A,
50
–60 Hz
Operating Range: 90–132V
AC/170-
250V AC
auto-ranging
Power (DC Option) Rating: 38–64V DC, 2.5A Rating: 38-64V DC, 14A
Power Consumption (W) 30 4 RAUs: 290 typical, 360 max.
8 RAUs: 500 typical, 630 Max.
Enclosure Dimensions
(e)
(height ´ width ´ depth)
89 mm × 438 mm × 381 mm
(3.5 in. × 17.25 in. × 15 in.)
2U
89 mm × 438 mm × 381 mm
(3.5 in. × 17.25 in. × 15 in.)
2U
54 mm x 286 mm x 281 mm
(2.13 in. × 11.25 in. × 11.13 in.)
Weight < 5.5 kg (< 12 lbs.) < 6.6 kg (< 14.5 lbs.) < 2.1 kg (< 4.6 lbs.)
a 6-type N, female connectors for FSN-W2-MH-1
, FSN-W2-MH-3, FSN-W4-MH-1, and FSN-W5-MH-1 Main Hub.
b 2-type N, female connectors for FSN-W1-19
21-1, FSN-W2-808519-1, FSN-W2-7575-1, FSN-W2-7070-1, FSN-W3-2626-1,
FSN-W4-702121-1-HP, FSN-W4-752121-1-HP, FSN-W5-851921-1-HP, and FSN-2500-2-WMAX RAUs.
c It is critical to system perfo
rmance that only SC/APC fiber connectors are used throughout the fiber network, including fiber
distribution panels.
d FSN-W1-MH-2-1P, FSN-W2-MH-3-1P, FSN-W3-
MH-1P, FSN-W4-MH-1P, and FSN-W5-MH-1P support only one pair, SP/APC
fibers.
e Excluding angle-brackets for 19''