User's Manual

RAU LED Indicators
5-6 InterReach Fusion Installation, Operation, and Reference Manual
CONFIDENTIAL D-620610-0-20 Rev D
NOTE: For system performance, it is important that you use only low loss,
solid copper center conductor CATV cable with quality F connectors that use
captive centerpin conductors. Refer to Appendix A for specific information.
5.3 RAU LED Indicators
Upon power up, the RAU goes through a two-second test to check the LED lamps.
During this time, the LEDs blink green/green red/red, letting you visually verify that
the LED lamps and the firmware are functioning properly.
NOTE: Refer to Section 9 for troubleshooting using the LEDs.
Status LEDs
The RAU status LEDs can be in one of the states shown in Table 5-4. These LEDs
can be:
off
steady green
steady red
There is no off state when the unit’s power is on.
Table 5-4 Remote Access Unit LED States
LED State Indicates
Off
Off
The RAU is not receiving DC power.
Green
Green
The RAU is powered and is not indicating a fault
condition. Communication with the Fusion Hub
is normal; however, the system test may need to
be performed or a warning condition may exist
(use AdminBrowser to determine this).
Green
Red
The RAU is indicating a fault or lockout condi-
tion, but communication with the Fusion Hub is
normal.
Red
Red
The RAU is reporting a fault and is not able to
communicate with the Fusion Hub
Green (60-ppm)
Green (60-ppm)
The RAU is reporting a lockout condition, but
communication with the Fusion Hub is normal.
LINK
ALARM
LINK
ALARM
LINK
ALARM
LINK
ALARM
LINK
ALARM