User's Manual

Main Hub Specifications
3-10 InterReach Fusion Installation, Operation, and Reference Manual
CONFIDENTIAL D-620610-0-20 Rev D
3.4 Main Hub Specifications
Table 3-4 Main Hub Specifications
Specification Description
Enclosure Dimensions (H
u W u D)
a
:
a. Excluding angle brackets for the 19” rack mounting of the Hub.
89 mm x 438 mm x 381 mm (3.5 in. x 17.25 in. x 15 in.) 2U
Weight <5.5 kg (<12 lb)
Operating Temperature 0° to +45°C (+32° to +113°F)
Non-operating Temperature –20° to +85°C (–4° to +185°F)
Operating Humidity, non-condensing 5% to 95%
External Alarm Connector
(contact closure)
1 9-pin D-sub, female
Maximum: 40 mA @ 40V DC
Typical: 4 mA @ 12V DC
ADMIN/LAN Interface Connector 1 RJ-45, female
1 9-pin D-sub, male for optional modem
Fiber Connectors
4 Pair, SC/APC
b
b. It is critical to system performance that only SC/APC fiber connectors are used throughout the fiber network, including
fiber distribution panels.
NOTE: The Fusion One Port Main Hub (PN:
FSN-1-MH-1P) configuration is a cost reduced version of the
Fusion Main Hub and supports only one Expansion Hub (up
to 8 RAUs).
RF Connectors 6 N, female (50 Ohm), 1 Downlink/Uplink pair per band
LED Fault and Status Indicators Unit Status (1 pair):
•Power
Main Hub Status
Downstream Unit/Link Status (1 per fiber port):
Link/E-Hub/RAU
AC Power Rating 100/240V AC, 1A, 50-60 Hz
Operating Range: 90-132V AC/170-250V AC auto-ranging
Power Consumption (W) 30
MTBF 117,972 hours