User's Manual

Table Of Contents
Help Hot Line (U.S. only): 1-800-530-9960 7-45
D-620616-0-20 Rev A CONFIDENTIAL
Interfacing the Fusion Wideband Main Hub to an RF Source
Connecting a Fusion Wideband Main Hub RF Band to Multiple
BTSs
WARNING: Only LGC personnel or LGC-authorized installation per-
sonnel should connect the Fusion Wideband Main Hub to a base station
or repeater. Exceeding the maximum input power could cause failure
of the Fusion Wideband Main Hub (refer to Section 5.2 on page 5-4 for
maximum power specifications). If the maximum composite power is
too high, attenuation is required.
You can use power combiner/splitters to connect a Fusion Wideband Main Hub RF
Band to multiple base stations, as shown in Figure 7-26.
Figure 7-26 Connecting a Fusion Wideband Main Hub to Multiple Base Stations
N-male to N-male
Coaxial Jumper Cables
N-male to N-male
Coaxial Jumper Cable
to Repeater or
Base Station
between Combiner/Splitter and
N-male to N-male
Coaxial Jumper Cables
between Combiner/Splitter and
Fusion Main Hub’s Uplink Port Fusion Main Hub’s Downlink Port fo
r
2 x 1 Power
Combiner/Splitter
2 x 1 Power
Combiner/Splitter
BTS 1
UL DL
BTS 2
UL DL
Insert attenuators, if needed
for each on Band 1 or Band 2 either Band 1 or Band 2
Band 1
Band 2
Band 3
UL1 UL2
UL3
DL1
DL2
DL3
AC Power
Alarms