3-4
+ is for North and East.
– is for South and West.
The Name fields support up to 40 characters.
Click on the Link name in Systems screen.
The following screen appears (figure 3-6).
Figure 3-6
This screen shows all the parameters of the system, including alarms. Note that settable
parameters have “Change Value” or “Change Status” tabs. (Scroll down to see the Remote and
Host details).
The settable parameters are “PA Mute” of the Remote unit and Gains (Host and Remote, FWD
and RVS).
Click on “Change Value” or “Change Status” of the parameter you want to change, change the
value / status and click “Save”.
Until actual change is applied, a green note advising that a change is pending will appear.
Whenever this sign appears in the Gains field, note that the Actual Gain differs from the Set
Gain, implying that the ALC is in operation.
At the bottom of the screen there are three tabs:
“Reset Link” soft-resets the internal software of the Remote unit, then the Host unit.
“Set Time to Host” synchronizes the Host clock with the PC clock.
“Set Time to Remote”- respectively.