User's Manual

WiMax Optical Fiber Repeater 10W Installation and Operation Manual
Document No. 913011900 Rev. 1.1 Proprietary Document
2-3
Required Tools and Test Equipment
Table
2-3: Tools and test equipment for Repeater installation
Equipment Use
Ring/Open spanner ½ Install the Repeater units
Ring/Open spanner 7/16” Close the ground lugs
Ring/Open spanner 30-32 mm Open/close DIN 7/16 connectors
Digital Voltmeter Fluke 77 or
equivalent
Measure voltage and polarity for the installation process
Pilot Scanner / Drive Test Set Measure donor pilot signal levels
Frequency domain Reflectometer Check Insertion loss and VSWR for system RF Cables
Network Analyzer (optional) Check Insertion loss and VSWR for system RF Cables
Signal Generator Check Isolation between antennas
Spectrum Analyzer Check Repeater Output Power
30dB 50W attenuator (Cellular Band) Protect RF Test equipment from overpowered signals
Type N 50 Termination (1 unit) Terminate antenna port during off-air test procedures
Standard calibrated test cables Test equipment usage
Laptop PC equipped with Windows
2000 with Service Pack 3 or Windows
XP, SP2
Configure, control, and monitor the Repeater through the
RS-232 communication port
NOTE: For antenna installation tools, refer to your antenna
installation guide.
2.2 Run Sweep Test
Before installing the Repeater, check mechanical assembly of all RF
connectors, run a sweep test of the RF cables and record the cables loss.
Perform the sweep test using a Site Master analyzer or a Network Analyzer.
Perform open/short tests on the distribution RF cables.
Record the following parameters for each RF cable:
o
Insertion loss of the cable
o
Return loss (VSWR)
If you detect a fault in any of the cables, repair it and re-check until all the
cables are good.
NOTE: Record the information for reference in Appendix D. This
information is used during the setup procedure.