User Manual

ADCP-75-116 Issue A August 2001 Section 2: Description
Page 2-25
©
2001,
ADC
Telecommunications,
Inc.
Weather
resistance NEMA-3R,
removable
dust
filter
Operating
temperature –3
to
50º
C
(–22º
to
122º
F)
Storage
temperature –4
to
70º
C
(–40º
to
158ºF)
Humidity 10%
to
90% No
condensation
External
alarm
connector Screw-type
terminals External
alarm
inputs
AC
power
connection 3/4-
or
1/2-inch
conduit Per
local
code
or
practice.
Antenna
cable
connector N-type
(female)
Fiber
optic
cable
size
0.375
to
0.875
inch
(10
to
22
mm)
diameter
cable
Lightning
protection 20
kA
IEC
1000-4-5
8/20
µs
waveform
Service
connector DB-9
(female) RS-232
DTE
interface
Battery
backup
operation 1
hour
Power
input 120
or
240
VA C ,
50
or
60
Hz Operation
on
240
VAC
requires
installation
of
the
240
VA C
out-
let
(accessory)
Power
consumption 10
Amps
at
120
Va c
Current
rating 85–250
VAC ,
???
Amp
input
Reliability
at
25ºC MTBF
50,000
hours Excluding
fans,
battery,
and
fil-
ter
Table 2-5. System Specifications, continued
PARAMETER SPECIFICATION REMARKS