User Manual
Table Of Contents
- SECTION 1: Overview
- SECTION 2: Description
- SECTION 3: Host Unit Installation
- SECTION 4: Operation
- SECTION 5: Maintenance
- SECTION 6: General Information
- ABOUT THIS MANUAL
- RELATED PUBLICATIONS
- ADMONISHMENTS
- GENERAL SAFETY PRECAUTIONS
- STANDARDS CERTIFICATION
- LIST OF ACRONYMS AND ABBREVIATIONS
- SECTION 1: Overview
- SECTION 2: Description
ADCP-75-116 • Issue A • August 2001 • Section 2: Description
Page 2-23
©
2001,
ADC
Telecommunications,
Inc.
RF Forward Path - SMR 800 MHz
System
bandwidth
15
MHz
Frequency
range 851
to
866
MHz
Gain
of
host/remote
link 85
±
3
dB
at
band
center
and
room
temperature
Includes
power
amplifier.
Gain
flatness <
±
1.5
dB
across
freq.
range
<
±
1
dB
variation
across
any
1.25
MHz
channel
Gain
variation <
±
3
dB
over
temp
and
unit-to-
unit
Gain
adjustment Software
adjustable
in
30
steps
of
1
±
0.25
dB
Out-of-band
rejection –40
dB
bandwidth
<
30
MHz
Propagation
delay <
6
µs
maximum Excludes
fiber
delay.
Variable
propagation
delay
adjustability
Software
adjustable
in
1µs
incre-
ments
over
a
0
to
60
µs
range
Spurious
(self
generated) <
–13
dBm
at
remote
output
Spurious
free
dynamic
range <
–60
dBc
Tx
peak
to
average >
10
dB
Intermodulation <
–55
dBc
at
remote
output
Maximum
composite
RF
input
signal
level
–10
to
–40
dBm,
adjustable
in
1
dB
increments
(The
host
requires
a–40
dB
input
signal
level)
–40
dBm
with
host
attenuator
at
0
dB
–10
dBm
with
host
attenuator
at
30
dB
Tx
path
insertion
loss 2.5
dB
maximum
Output
power ≥
50
Watts
at
power
amplifier
output
30
Watts
(45
dBm)
at
remote
antenna
port
RF Reverse Path - SMR 800 MHz
System
bandwidth 15
MHz
Frequency
range 806
to
821
MHz
Gain 30
±
2
dB
at
band
center
Gain
flatness <
±
1.5
dB
across
frequency
range
<
1
dB
variation
across
any
1.25
MHz
channel
Gain
variation <
±
3
dB
over
temperature
and
unit-to-unit
Out-of-band
rejection –40
dB
bandwidth
<
30
MHz
Table 2-5. System Specifications, continued
PARAMETER SPECIFICATION REMARKS