User Manual

ADCP-75-114 Issue 2C January 2002
Page 12
©
2002,
ADC
Telecommunications,
Inc.
2.5.1 Forward and Reverse Path Coaxial Cable Connections
Use
the
following
procedure
to
install
the
forward
and
reverse
path
coaxial
cables
that
link
the
RIU
to
the
DHU:
1.
Locate
the
forward
and
reverse
path
coaxial
cables
that
were
routed
to
the
RIU
from
the
DHU.
Note:
The
procedures
for
routing
the
reverse
and
forward
path
coaxial
cables
from
the
DHU
to
the
RIU
and
for
connecting
the
cables
to
the
DHU
are
covered
in
the
Digivance
ICS
System
Installation
and
Operation
Manual
(See
Related
Publications
section)
which
is
provided
with
the
DHU.
2.
Terminate
each
cable
with
a
type
N
male
connector
following
the
connector
supplier’s
recommendations.
3.
Connect
the
forward
path
cable
to
the
FORWARD
OUT
connector
on
the
RIU
front
panel
as
shown
in
Figure
9.
16652-A
FORWARD OUT
CONNECTOR
REVERSE IN
CONNECTOR
TYPE-N MALE CONNECTOR
Figure 9. FORWARD OUT and REVERSE IN Coaxial Cable Connections
4.
Connect
the
reverse
path
cable
to
the
REVERSE
IN
connector
on
the
RIU
front
panel
as
shown
in
Figure
9.
5.
Dress
and
secure
cables
at
the
RIU.
2.5.2 Antenna Coaxial Cable Connection
Use
the
following
procedure
to
install
the
coaxial
cable
that
links
the
RIU
to
the
donor
antenna:
Note:
To
comply
with
Maximum
Permissible
Exposure
(MPE)
requirements,
the
maximum
composite
output
from
the
antenna
cannot
exceed
1000
watts
EIRP
and
the
antenna
must
be
permanently
installed
in
a
fixed
location
that
provides
at
least
6
meters
(20
feet)
of
separation
from
all
persons.