1.9 Specifications
The
specifications
for
the
RIU
are
provided
in
Table
2.
All
specifications
apply
after
a
five
minute
warm-up
period.
Table 2. Remote Interface Unit Specifications
PARAMETER SPECIFICATION REMARKS
Environmental
Operating
Temperature 0º
to
50º
C
(32º
to
122º
F)
Storage
Temperature
–30º
to
+70º
C
(–22
to
158º
F)
Humidity
No
condensation
Weather
resistance
Indoor
installation
only
RF Forward Path
800
MHz
unit 869
to
894
MHz
1900
MHz
unit
1930
to
1990
MHz
RF
Gain
+9
to
+40
dB
Adjustable
in
1
dB
steps
Gain
Variation
±
1.5
dB
Over
frequency,
temperature,
and
unit-to-unit.
Gain
stepsize
accuracy
±
(0.2
+
3%
of
gain
setting
in
dB)
dB
Output
power
–20
dBm
composite
maximum
to
Digivance
ICS
input
With
proper
input
signal
and
attenuation
setting
Input
level
–29
dBm
composite
maximum
To
drive
Digivance
ICS
DHU
VSWR
1.5:1
or
better,
both
ports
RF Reverse Path
800
MHz
unit
824
to
849
MHz
1900
MHz
unit
1850
to
1910
MHz
RF
Gain
800
MHz
1900
MHz
+28
to
+59
dB
+33
to
+64
dB
Adjustable
in
1
dB
steps
Gain
Variation
800
MHz
1900
MHz
±1.5
dB
±3
dB
Over
frequency,
temperature,
and
unit-to-unit.
Gain
stepsize
accuracy
±
(0.2
+
3%
of
gain
setting
in
dB)
dB
Output
power
800
MHz
1900
MHz
+29
dBm
composite
maximum
+34
dBm
composite
maximum
When
driven
with
Digivance
ICS
DHU
Input
level
(Recommended
composite
maximum)
–30
dBm
From
Digivance
ICS
DHU
output
VSWR
1.5:1
or
better,
both
ports
OIP3
≥
+46
dBm
(continued)