User's Manual
ADCP-75-110 • Issue 2B • July 2001
Page 10
©
2001,
ADC
Telecommunications,
Inc.
FRONT PANEL
CABLE MANAGEMENT
TRAY
MOUNTING
BRACKET
(BOTH SIDES)
16422-A
3.5 INCHES
(89 mm)
11.4 INCHES
(290 mm)
15.3 INCHES
(389 mm)
17.2 INCHES
(437 mm)
Figure 6. Digital Expansion Unit
1.4.1 Primary Components
The
DEU
consists
of
two
electronic
circuit
board
assemblies
and
a
power
supply
that
are
mounted
within
a
powder-coated
sheet
metal
enclosure.
The
metal
enclosure
provides
a
mounting
point
for
the
electronic
assemblies
and
serves
as
a
heat
sink.
Except
for
the
fan
units,
the
electronic
circuit
board
assemblies
are
not
user
replaceable.
The
DEU
is
designed
for
use
within
a
non-condensing
indoor
environment
such
as
inside
a
wiring
closet
or
cabinet.
All
controls,
connectors,
and
indicators
are
mounted
on
the
DEU
front
panel
for
convenient
access.
Cable
management
functions
for
the
power
and
fiber
optic
cables
are
provided
by
a
cable
management
tray
that
extends
outward
from
the
DEU
front
panel.
1.4.2 Mounting
The
DEU
may
be
used
in
both
rack-mount
and
wall-mount
applications.
For
rack
mount
applications,
a
pair
of
reversible
mounting
brackets
is
provided
that
allow
the
DEU
to
be
mounted
in
either
a
19-inch
or
23-inch
EIA
or
WECO
equipment
rack.
When
rack-mounted,
the
front
panel
of
the
DEU
is
flush
with
the
front
of
the
rack.
The
cable
management
tray
extends
3.9
inches
(99
mm)
beyond
the
front
panel.
For
wall-mount
applications,
a
pair
of
holes
is
provided
in
the
cable
management
tray
which
allow
the
DEU
to
be
mounted
on
any
flat
vertical
surface.
The
DEU
should
be
oriented
with
the
front
panel
facing
upward
when
wall-mounted.
Fasteners
are
provided
for
rack-mount
applications.
1.4.3 Fault Detection
The
DEU
is
designed
to
detect
internal
circuitry
faults
or
loss
of
system
inputs.
Various
front
panel
Light
Emitting
Diode
(LED)
indicators
turn
from
green
to
red
or
yellow
when
a
fault
is
detected
or
when
an
optical
input
is
lost.
The
DEU
transports
the
fault
information
to
the
DHU
or
supporting
DEU
over
the
fiber
optic
link.
A
corresponding
port
LED
at
the
DHU
or
DEU
turns
from
green
to
red
when
the
DEU
reports
a
fault.