Table 11. Fault Isolation and Troubleshooting, continued
Alarm Type Major
LED Indicators DHU or DEU:
DRU:
OK/NOK - Red or blinking Red - All other LEDs are green
STATUS - Green
Problem The DHU or DEU is not receiving an optical signal from the DRU.
POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS
1.
Faulty
reverse
path
optical
link
between
DHU
or
DEU
and
DRU.
2.
Faulty
optical
receive
port
at
DHU
or
DEU;
or
faulty
optical
transmit
port
at
DRU.
1.
Test
optical
link
and
repair
or
replace
if
faulty
(see
Subsection
5.4.2).
2.
Test
optical
ports.
Replace
DHU,
DEU,
or
DRU
if
port
is
faulty
(see
Subsection
5.4.1).
Alarm Type Major
LED Indicators DHU or DEU:
DRU:
OK/NOK - Red or blinking Red - All other LEDs are green
STATUS - Red or Blinking Red
Problem The DHU or DEU is not receiving an optical signal from the DRU and the DRU is not receiving
an optical signal from the DHU or DEU; or the DRU detects an internal circuitry fault.
POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS
1.
Faulty
forward
and
reverse
path
optical
link
between
the
DHU
or
DEU
and
DRU
2.
Faulty
DRU.
1.
Test
optical
link
and
repair
or
replace
if
faulty
(see
Subsection
5.4.2)
2.
Replace
DRU.
Alarm Type Major
LED Indicators DHU or DEU:
Supported DEU:
All LEDs are green
HOST PORT - Red or blinking Red - All other LEDs are green
Problem The supported DEU is not receiving an optical signal from the DHU or DEU.
POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS
1.
Faulty
forward
path
optical
link
between
DEU
or
DHU
and
supported
DEU.
2.
Faulty
optical
transmit
port
at
DHU
or
DEU
or
faulty
optical
receive
port
at
supported
DEU.
1.
Test
optical
link
and
repair
or
replace
if
faulty
(see
and
5.4.2).
2.
Test
optical
ports.
Replace
DHU,
DEU,
or
sup-
ported
DEU
if
port
is
faulty
(see
Subsection
5.4.1).
Alarm Type Major
LED Indicators DHU or DEU:
Supported DEU:
OK/NOK - Red or blinking Red - All other LEDs are green
All LEDs are green
Problem The DHU or DEU is not receiving an optical signal from the supported DEU.
POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS
1.
Faulty
reverse
path
optical
link
between
DEU
or
DHU
and
supported
DEU.
2.
Faulty
optical
receive
port
at
DHU
or
DEU
or
faulty
optical
transmit
port
at
supported
DEU.
1.
Test
optical
link
and
repair
or
replace
if
faulty
(see
and
5.4.2).
2.
Test
optical
ports.
Replace
DHU,
DEU,
or
sup-
ported
DEU
if
port
is
faulty
(see
Subsection
5.4.1).
Alarm Type Major
LED Indicators DHU or DEU:
Supported DEU:
OK/NOK - Red or blinking Red - All other LEDs are green
HOST PORT - Red or blinking Red - All other LEDs are green
Problem The DHU or DEU is not receiving an optical signal from the supported DEU and the supported
DEU is not receiving an optical signal from the DHU or DEU.
POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS
1.
Faulty
forward
and
reverse
path
optical
link
between
DEU
or
DHU
and
supported
DEU.
1.
Test
optical
link
and
repair
or
replace
if
faulty
(see
and
5.4.2).
(continued)