ADCP-75-110 Issue 2B July 2001
Page 47
©
2001,
ADC
Telecommunications,
Inc.
5.3 Fault Isolation and Troubleshooting
Table
11
provides
fault
isolation
and
troubleshooting
guidelines.
When
a
problem
is
reported,
note
the
type
of
alarm
generated
(minor,
major,
or
none)
and
any
problems
that
may
be
observed.
Then
check
the
LED
indicators
on
the
DHU
and
note
any
that
are
red,
yellow,
or
off.
If
a
Port
1–6
OK/NOK
LED
indicator
is
any
color
but
green,
check
the
LED
indicators
on
the
connected
DEUs
and/or
DRUs.
When
the
required
information
has
been
obtained,
locate
the
problem
in
Table
11,
check
out
the
suggested
possible
causes,
and
take
corrective
action
as
required.
Table 11. Fault Isolation and Troubleshooting
Alarm Type Minor
LED Indicators DHU or DEU: UNIT - Yellow - All other LEDs are green
Problem The DHU or DEU is overheating.
POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS
1.
Air
intake
or
exhaust
openings
to
DHU
or
DEU
chassis
blocked.
2.
Ambient
temperature
>
50º
C/122º
F.
3.
Faulty
fan.
1.
Remove
cause
of
air-flow
blockage.
2.
Reduce
ambient
temperature.
3.
Replace
fan
(see
Subsection
5.5).
Alarm Type Major
LED Indicators DHU or DEU: UNIT - Red
Problem The DHU or DEU detects an internal circuitry fault.
POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS
1.
Faulty
DHU
or
DEU.
1.
Replace
DHU
or
DEU.
Alarm Type Major
LED Indicators DHU or DEU:
DRU:
OK/NOK - Red or blinking Red - All other LEDs are green
STATUS - Off
Problem The DRU is not powered.
POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS
1.
DC
power
cable
open.
2.
No
power
or
insufficient
power
output
from
ac/dc
power
converter,
DHU,
or
DEU.
3.
Faulty
DRU.
1.
Test
cable
for
continuity
and
repair
or
replace
if
faulty.
2.
Check
DC
voltage
level
at
the
DRU
(see
Subsection
5.4.3).
Replace
converter,
DHU,
or
DEU
(whichever
applies)
if
voltage
is
not
within
34
to
48
Vdc.
3.
Replace
DRU.
Alarm Type Major
LED Indicators DHU or DEU:
DRU:
All LEDs are green
STATUS - Red or blinking Red
Problem The DRU is not receiving an optical signal from the DHU or DEU.
POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS
1.
Faulty
forward
path
optical
link
between
DHU
or
DEU
and
DRU
2.
Faulty
optical
transmit
port
at
DHU
or
DEU;
or
faulty
optical
receive
port
at
DRU.
1.
Test
optical
link
and
repair
or
replace
if
faulty
(see
Subsection
5.4.2).
2.
Test
optical
ports.
Replace
DHU,
DEU,
or
DRU
if
port
is
faulty
(see
Subsection
5.4.1).
(continued)