Table 8. Digital Expansion Unit LED Indicators
INDICATOR COLOR DESCRIPTION
UNIT
LED
Green
Yellow
Red
Off
Indicates
when
the
DEU
is
normal
or
faulty.
DEU
in
normal
state,
no
faults
detected.
DEU
in
power-up
state
or
DEU
high
temperature
fault
detected.
(see
Note)
DEU
internal
fault
detected.
(see
Note)
AC
power
off
to
DEU
or
DEU
internal
fault.
HOST
PORT
LED
Green
Red
(steady
or
blinking)
Off
Indicates
when
the
optical
inputs
from
the
DHU
or
supporting
DEU
are
normal
or
lost.
DHU
or
supporting
DEU
in
normal
state,
no
faults
detected.
No
forward
path
optical
signal
from
DHU
or
supporting
DEU
detected
or
excessive
forward
path
errors
detected.
(see
Note).
DEU
internal
fault.
PORT
1–6
OK/NOK
LEDs
Green
Yellow
Red
Red
(blinking)
Off
Indicates
if
any
connected
DEU
or
DRU
is
normal
or
faulty
or
if
the
optical
inputs
from
any
connected
DEU
or
DRU
are
normal
or
lost.
DRU
or
remote
DEU
in
normal
state,
no
faults
detected.
DEU
in
power-up
state.
Fault
detected
in
any
connected
DEU
or
DRU,
*no
reverse
path
optical
signal
from
any
connected
DEU
or
DRU
detected,
or
excessive
reverse
path
errors
detected
from
any
connected
DEU
or
DRU.
(see
Note)
*No
reverse
path
optical
signal
from
any
connected
DEU
or
DRU
detected.
Port
disabled
(via
front
panel
switch)
or
DEU
internal
fault.
*Early
versions
of
the
DEU
use
a
steady
red
LED
to
indicate
all
major
fault
conditions.
Later
versions
of
the
DEU
use
a
blinking
red
LED
to
indicate
no
optical
signal
received
from
the
connected
DRU
or
DEU.
Note:
Detection
of
any
fault
will
generate
an
alarm.
A
high
temperature
fault
will
generate
a
minor
alarm
(yellow
LED).
All
other
types
of
faults
will
generate
a
major
alarm
(red
LED).
Table 9. Digital Remote Unit LED Indicator
INDICATOR COLOR DESCRIPTION
STATUS
LED
Green
Yellow
Red
Red
(blinking)
Off
Indicates
if
the
DRU
is
normal
or
faulty
or
if
the
forward
path
optical
inputs
to
the
DRU
are
normal
or
lost.
DRU
in
normal
state,
no
faults
detected.
DRU
in
power-up
state.
DRU
internal
fault
detected,
*no
forward
path
optical
signal
detected,
or
excessive
forward
path
errors
detected.
(See
Note)
*No
forward
path
optical
signal
from
the
DHU
or
DEU
detected.
DC
power
off
to
DRU
or
DRU
internal
fault.
*Early
versions
of
the
DRU
use
a
steady
red
LED
to
indicate
all
major
fault
conditions.
Later
versions
of
the
DRU
use
a
blinking
red
LED
to
indicate
no
optical
signal
received
from
the
DHU
or
DEU.
Note:
Detection
of
any
fault
will
generate
an
alarm.
A
high
temperature
fault
will
generate
a
minor
alarm
(yellow
LED).
All
other
types
of
faults
will
generate
a
major
alarm
(red
LED).