Installation Manual

ADCP-75-112 Issue 2A June 2001
Page 13
©
2001,
ADC
Telecommunications,
Inc.
5. Hold
the
antenna
in
position
for
mounting
on
the
hard
ceiling.
6. Mark
the
location
of
the
two
antenna
bracket
mounting
holes
on
the
hard
ceiling.
7. Drill
a
1/8-inch
(3
mm)
hole
at
each
of
the
two
locations
marked
in
step
6.
8. Secure
the
antenna
mounting
bracket
to
the
hard
ceiling
using
two
#4
screws
(must
be
provided
by
installer).
9. Route
antenna
cable
to
DRU.
Fig 10-A
SMA CONNECTOR
ORIENT ANTENNA SO FLAT SIDES ARE
PERPENDICULAR WITH HALLWAY WALLS
NOTE: TO COMPLY WITH MAXIMUM
PERMISSIBLE EXPOSURE (MPE) REQUIREMENTS,
ANTENNAS MUST BE INSTALLED TO PROVIDE AT
LEAST 20 CENTIMETERS OF SEPARATION FROM
ALL PERSONS PER FCC 47 CFR PART 2.1091.
Figure 10. 1900 MHz Ceiling-Mount Hallway Antenna Installation
2.5.4 800 MHz Directional Panel Antenna
The
800
MHz
directional
panel
antenna
is
designed
to
mount
vertically
on
one
side
of
the
coverage
area.
Mount
the
directional
panel
antenna
as
shown
in
Figure
11
and
as
described
in
the
following
procedure:
1. Drill
holes
in
antenna
plastic
cover
for
fasteners
(see
rear
side
for
hole
location).
2. Drill
5/8-inch
(16
mm)
hole
in
wall
for
antenna
cable.
3. Insert
antenna
cable
through
hole
in
wall.
4. Place
antenna
on
wall,
making
sure
arrow
on
rear
side
of
antenna
points
up.
5. Drill
holes
in
wall
for
fasteners
(installer
provided).
6. Secure
antenna
to
wall
with
fasteners.
7. Route
antenna
cable
to
DRU.