Installation Manual

ADCP-75-112 Issue 2A June 2001
Page 11
©
2001,
ADC
Telecommunications,
Inc.
16244-A
THREADED SPACER
(REMOVE IF NOT NEEDED)
CEILING
TILE
7/8-14 NYLON HEX
JAM NUT
I-INCH (25 mm)
DIAMETER HOLE
SMA CONNECTOR
NOTE: TO COMPLY WITH MAXIMUM
PERMISSIBLE EXPOSURE (MPE) REQUIREMENTS,
ANTENNAS MUST BE INSTALLED TO PROVIDE AT
LEAST 20 CENTIMETERS OF SEPARATION FROM
ALL PERSONS PER FCC 47 CFR PART 2.1091.
Figure 8. 800 and 1900 MHz Ceiling-Mount Omnidirectional Antenna Installation
2.5.2 800 MHz Ceiling-Mount Hallway Antenna
The
800
MHz
ceiling
mount
hallway
antenna
is
designed
to
mount
in
the
center
of
long
corridors.
Mount
the
ceiling-mount
hallway
antenna
as
shown
in
Figure
9
and
as
described
in
the
following
procedure:
1. Remove
ceiling
tile.
2. Drill
1-inch
(25
mm)
hole
in
center
of
tile.
3. Insert
antenna
cable
through
hole.
4. Insert
threaded
stud
on
base
of
antenna
through
hole.
5. Secure
antenna
to
ceiling
tile
with
nylon
jam
nut.
6. Orient
antenna
so
flat
sides
are
perpendicular
with
hallway
walls.
7. Replace
ceiling
tile.
8. Route
antenna
cable
to
DRU.