User's Manual
Table Of Contents
ADCP-75-198 • Issue 1 • October 2005
Page 7
© 2005, ADC Telecommunications, Inc.
2.7 Install PCI Riser Cage
1. Align the PCI riser cage with the chassis and slide it into place.
2. Tighten the screws to secure the PCI riser cage.
2.8 Install Access Panel
1. Place the access panel on top of the server with the hood latch open.
2. Push down on the hood latch. The access panel slides to a closed position.
2.9 Slide Server Into Rack
After performing the SDR PCIx Host card installation procedure, slide server back into the rack:
1. Press the server rail-release latches and slide the server fully into rack.
2. Secure the server by tightening the thumbscrews.
3 SDR PCIx HOST CARD CABLING
3.1 Optical and Electrical Connections
Optical and electrical connections with the remote unit and GPS are supported by four optical
and two electrical ports. The electrical interface to the GPS is through coaxial cable connections
using two type SubMiniature version A (SMA) female connectors. Single-mode fiber provides
the optical connection between the SDR PCIx Host Card and Remote Units. The forward and
reverse ports provide the optical communication channel in a non-diversity system. The REV
DIV port provides receive optics for a diversity system. Each optical port uses a small form
factor LC-type optical transceiver. Modular optical transceivers are field replaceable and
available separately.
3.2 Coax Cabling
3.2.1 Coaxial Cable Requirements
SDR
PCIx Host card is equipped with
SMA
-type female 50-Ohm connectors for connecting the
timing input/output signals from the GPS unit. High performance, flexible, low loss 50-ohm
coaxial communications cable (RG316 or equivalent) should be used for all coaxial connections.
RF coaxial cable connectors are N-type (female) 50 Ohms input/output impedance.
Caution: To prevent damage to the server or expansion boards, power down the server and
remove all AC power cords before removing or installing the PCI riser cage.