User's Manual Part 9

Screen-Based Reference Remote Displays
Element Management System (EMS) 4.0 User Manual
89
For the download procedure, refer to Topic Topic 3.14, Downloading Program
Files, on page 50. Table 33 describes the components of the window.
Table 33: Prg Load Window Components
DISPLAY NAME DESCRIPTION
Operational State
Oper Mode This mode is not set here, merely indicated. (The mode is set
using the Opmode tool.) The host should be in a Normal
mode when starting the download. It then changes to
Program Load mode automatically.
Control Program File
<Unnamed Field> <Name><Version>.sr where
<
Name> = name of program being downloaded
<Version> = major.minor.rev.build
Select Click on this button to browse for and open the program file
you want to download.
Load Click on this button to download the selected program.
Compare Click on this button to compare the version of the selected
control program with the version of the control program
already installed on the unit.
Validate Click on this button to determine whether the FPGA on the
remote unit is in a functional state in which an FPGA can be
downloaded.
For newer hardware, the FPGA will be reported as “not
functional” if the FPGA software did not successfully
download to begin with. If the FPGA is not functional, the
RF system will be in alarm.
NOTE: The response to this button click should be
disregarded for older hardware. The older hardware can be
identified by the FPGA version being “UNKNOWN” (in the
FPGA Program field). On this older hardware, the FPGA is
not downloadable.
Software Info
Init-er Remote Initialization Program version