5.5.18 SET THRESHOLD
This command can be used to set the remote unit forward path attenuation. This
setting affects the strength of the forward path RF analog signal transmitted from
the remote unit antenna.
To set an alarm threshold
1. Enter a command in the following format
DEMS Site_Name SET THRESHOLD RemoteFwdAtt Threshold_Value
(or)
DEMS Node_Number SET THRESHOLD RemoteFwdAtt Threshold_Value
where Site_Name is the site name of the network element, Node_Number
is the Host Node or Remote Node value (as displayed in the Maintenance
interface View Catalog window),
RemoteFwdAtt is the parameter name and
Threshold_Value is the desired value. Threshold_Value must be a
numeric entry in an integer or decimal format such as shown in the examples
below. Use Site_Name = ALL to set all network elements to the same
value.
NOTE: For exact threshold names, see the preceding command.
2. Look for a response like this
1130 23-Mar-01 DEMS MainTower SET THRESHOLD RemoteFwdAtt 22\
RemoteFwdAtt 22 \
END
where the second line gives the resulting attenuation setting.
Examples
DEMS WattsvilleCivic SET THRESHOLD HostFwdAtt 22
DEMS ALL SET THRESHOLD HostFwdAtt 22