User's Manual Part 9
Commands Section 9
Element Management System (EMS) 4.0 User Manual
114
Examples
DEMS OwatWalMart SET ALARMFILTER 3P3Volt Off
DEMS 11 SET ALARMFILTER 3P3Volt Off
DEMS All SET ALARMFILTER ALL Off
5.5.17 GET THRESHOLD
This command can be used to determine the current value for remote forward
attenuation.
To determine thresholds
1. Enter a command in the following format:
DEMS Site_Name GET THRESHOLD RemoteFwdAtt
(or)
DEMS Node_Number GET THRESHOLD RemoteFwdAtt
where Site_Name is the site name of the network element, Node_Number
is the Host Node or Remote Node value (as displayed in the Maintenance
interface View Catalog window), and
RemoteFwdAtt is the parameter
name for remote forward attenuation. An
ALL command can also be entered;
it returns the attenuation setting, plus the current operating mode and band
(for reference in setting attenuation)
.
2. Look for a response like this
1130 23-Mar-01 DEMS(33 HOST.19)Ellsworth GET THRESHOLD
RemoteFwdAtt \
RemoteFwdAtt 1 \
END
where the second line gives the current threshold (in this case, 1).
If an ALL command is entered, the response includes the operating mode and
band for reference in setting the mode.
Examples
DEMS JanesvilleCivic GET THRESHOLD ALL
DEMS 33 GET THRESHOLD RemoteFwdAtt