User's Manual Part 9
NOC-NEM Interface Commands
Element Management System (EMS) 4.0 User Manual
97
• Host is listed first, then remote.
• Values given, in order, are: host node number and host site name,
remote node number and remote site name, and site number (one per
host remote pair).
Below is an example of a single line returned:
(37)Askov & (36)Tower & 12 \
In this example:
•
(37) is the host node number, Askov is the host site name
•
(36) is the remote node number, Tower is the remote site name
•
12 is the site number for this host/remote pair
NOTE: You cannot enter this command for a network element. If you try to, EMS
will send back a
REJECTED message such as shown below:
1130 23-Mar-01 DEMS GracesFood GET CATALOG \
REJECTED \
END
5.5.2 GET ALARMSUMMARY
This command can be used to display a summary of all alarm indicators in
network elements currently known to EMS. For each alarm indicator, the possible
values are
Green (no alarm), Yellow (minor alarm), or Red (major alarm).
To get a summary of all current alarms
1. Enter the following:
DEMS ALL GET ALARMSUMMARY
2. Look for a response like this:
Apr 3, 2003 1:10:11 PM: DEMS ALL GET AlarmSummary \
(35 Host.11) EmbarrassMinn Green & (34 Remote.11) Night-
falls Green \
(37 Host.12) Askov Green & (36 Remote.12) Tower Green \
END