User's Manual Part 8

Host Displays Section 7
Element Management System (EMS) 4.0 User Manual
74
4.4.4 Host DC Pwr Window
The host DC PWR (DC Power) window, shown in Figure 65, contains dashboard
displays with readings from the temperature sensor and voltage supply sensors on
the host unit control board. Table 17 describes the dashboard displays.
Sec Rx Errors Multiple errors on secondary fiber. Error rate has
exceeded 10
–6
(one bit error per million bits).
Table 14: Host Synthesizer and Band Alarms When Faulted
ALARM NAME DESCRIPTION
Pri Fwd Mux Lock The forward path primary fiber phase-locked-loop is
out of lock.
Ref Synth Lock The reference synthesizer is out of lock.
B Laser Mux Fault The secondary fiber phase-locked-loop is out of lock.
Table 15: FPGA Alarm When Faulted
INDICATOR NAME DESCRIPTION
Host FPGA Fault Fault was reported in FPGA chip on Host PCIx Card.
Table 16: Host Band Indicator
INDICATOR NAME DESCRIPTION
Band Indicates the RF bandwidth and sub-band at which this
unit is running. If the host unit and remote unit are at
different bands, a Hardware Mismatch alarm is
reported (for more information, see Topic 4.4.1, Host
Alarms Window, on page 69).
Table 13: Host Optics Alarms When Faulted (Continued)
ALARM NAME DESCRIPTION