User's Manual Part 5

Task-Based Reference Downloading Program Files
Element Management System (EMS) 4.0 User Manual
51
To load a program file
1. Load programs from source CD-ROM to known folder on EMS computer.
2. In EMS, select names of a host/remote pair from View menu.
3. Click on the host or remote Prg Load tab (as appropriate) to view the host or
remote program load window, shown in Figure 42.
4. Click on the Select button and browse to find the program to be loaded.
5. Depending in whether the file being loaded is a control program or FPGA,
proceed as follows:
a. If loading a control program, click on the Compare button to verify that
the file you are about to load is a newer version (greater version number)
than the program than the file already loaded on the unit
b. If loading an FPGA, first check the FPGA Program field. If it contains
the word “UNKNOWN,” the unit has older type hardware with a non-
replaceable FPGA, so you cannot proceed. If the field contains a version
number, click on the Validate button to verify that the FPGA is functional
(working). When you get a message back that the FPGA is functional,
you can proceed.
Table 3: Host and Remote Programs
<NAME> DESCRIPTION CAN DOWNLOAD?
Host Unit
SDR HIniter Host Initialization Program version No
SDR HReflsh Host Reprogram Program version No
HMR HstCP Host Control Program version Yes
FPGA Program Field Programmable Gate Array version Yes
Remote Unit
SDR RInter Remote Initialization Program version No
SDR RReflsh Remote Reprogram Program version No
HMR RemCP Remote Control Program version Yes
FPGA Program Field Programmable Gate Array version Yes