User's Manual Part 5

Task-Based Reference Determining RF Signal Levels
Element Management System (EMS) 4.0 User Manual
43
3.10 Determining RF Signal Levels
An operational host/remote pair has forward and reverse path RF signals passing
through it between the SDR BTS application and the cell phone user. The RF
signals are transported in digital format as RF spectrum data by way of fiber or
fiber-to-free-space optics links between the host unit (Host PCIx Card) and remote
unit (in both directions).
To view RF signal levels for a host/remote pair
1. From the View menu, select the site names of a host/remote pair.
2. Click on the host RF tab for the host or remote unit to view RF signal levels
and associated information for the selected unit (see Figure 33).
3. To interpret host display, see Topic 4.4.2, Host RF Window, on page 71. To
interpret remote display, see Topic 4.5.2, Remote RF Window, on page 82.
Figure 33. RF Display Example