Manual Part 3

Setting EMS Link Timeout, Cataloging Time, Demo Mode Section 3
Element Management System (EMS) 4.0 User Manual
34
To set the log file time interval using the NOC-NEM interface
Use the SET RECORD command (see Topic 5.5.10 on page 108).
NOTE: You cannot use NOC-NEM to define the log file name or directory.
3.6 Setting EMS Link Timeout, Cataloging Time, Demo Mode
Using the Preferences window (shown in Figure 16 on page 30), you can set the
following values:
•EMS Link Timeoutdefines the number of minutes EMS will try to
reestablish communication with a network unit before regarding it as
“not found.” When this occurs, EMS reports an EMS Link Status
alarm.
Cataloging Time—defines the number of seconds, at startup or in
response to a Tools
ÞRefresh Catalog request, that EMS spends
looking for units.
Demo Mode—controls whether EMS operates in demo mode or as a
normal working system. Demo mode can only be used when EMS is
not connected to a host/remote pair. Demo mode provides a simulated
system with two host/remote pairs.
NOTE: The Modem Initialization field, which also appears in the Preferences
window
, is not currently used.
To display the Preferences window
Select EditÞPreferences.
To set EMS link timeout
Use the pull-down menu to select from the available times shown in Figure 21.