Brochure
SPECIFICATIONS
GENERAL SPECIFICATIONS
Operating Temperature
Remote Unit: -30 to 50º C (-22 to 122º F)
Host Unit: 0 to 50º C (32 to 122º F)
Storage Temperature: -40 to 50º C (-40 to 122º F)
Humidity: 10% to 90% non-condensing
Lightning Protection Surge: 20kA IEC 1000-45 8/20 µs Waveform
Alarm Contacts - Host: Major/Minor contact closures
Alarm Indicators - Host: LEDs; red, green, and yellow
Alarm Indicator - Remote: LED; red
Element Management System: SNMP V2
REMOTE UNIT
Enclosure: NEMA 6/ IP-67
Mounting: Inside Pole, Pole Wrap, Wall or Strand
Dimensions (HxWxD)
Single: 28.3" x 9.5" x 6.20" (719mm x 241mm x 157mm)
Dual: 37.3" x 10.0" x 7.54" (947mm x 254mm x 192mm)
Weight
Single: <40 lbs. (18.1 kg)
Dual: <80 lbs. (36.3 kg)
Optical connectors: Sealed OptiTap with pigtail
RF connector: N-Type Female
HOST UNIT
Mounting: 19 and 23 inch rack
Dimensions (HxWxD) (max): 2 Rack Units (3.5" x 19.0" x 12.0")
(89mm x 483mm x 305mm)
Weight: (max): 18 lbs.
RF connector: N-Type Female
POWER SOURCE
Remote Unit Power Source: Wired to 90 – 265 VAC, 47 to 63 Hz
Optional 60 – 89 VAC, 47 to 63 Hz (single-band only)
Remote Unit Power Requirement
(at rated Power Output)
Single: <200 W
Dual: <400 W
Host Unit Power Source: 21 to 60 VDC floating
Host Unit Input Current: < 2A at 27.5VDC
Unless noted otherwise specifications are typical and subject to change
8/05 • 1337291
Digivance
®
Street-Level Coverage Solution
Digivance
®
Street-Level Coverage Solution (SCS)
6
www.adc.com • +1-952-938-8080 • 1-800-366-3891