User Manual

ADCP-75-179 Preliminary Issue A September 2004 Section 4: maintenance
Page 4-14
© 2004, ADC Telecommunications, Inc.
DISPLAY MESSAGE FORCED/INTERNAL SHUTDOWN Alarm Type: OVER POWER ALARM
PROBLEM: Output power from the LPA exceeds the maximum rating.
POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS
1. The power level of the RF forward path
composite input signal at the HU is too high.
2. The LPA has failed.
1. Check the power level of the RF composite input
signal at the HU and adjust to correct level. To
reset, use EMS to place Digivance system in
standby mode and then place system back in
normal mode.
2. Replace LPA.
DISPLAY MESSAGE FORCED/INTERNAL SHUTDOWN Alarm Type: VSWR ALARM
PROBLEM: The VSWR exceeds threshold setting of 3:1.
POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS
1. The interface cable between the LPA and STM
is faulty or the interface cable connectors are
faulty.
2. The antenna cable or antenna cable connectors
are faulty.
3. The antenna or antenna system is faulty.
4.The STM qudraplexer has failed.
5. The LPA has failed.
1. Inspect interface cable and connectors and repair
or replace as needed.To reset, use EMS to place
Digivance system in standby mode and then place
system back in normal mode.
2. Inspect antenna cable and connectors and repair
or replace as needed.To reset, use EMS to place
Digivance system in standby mode and then place
system back in normal mode.
3. Check the antenna circuit for shorts or opens
(including lightning protector). To reset, use EMS
to place Digivance system in standby mode and
then place system back in normal mode.
4. Replace STM.
5. Replace LPA
Table 4-8. 35 Watt LPA Fault Isolation and Corrective Action, continued