User Manual
ADCP-75-179 • Preliminary Issue A • September 2004 • Section 3: Operation
Page 3-10
© 2004, ADC Telecommunications, Inc.
9. Install the external attenuator in the coaxial cable that is connected to the 851–869
FORWARD RF IN port at the HU.
10. Repeat steps 1–8 for the 935–940 forward path output port at the EBTS. Install the
external attenuator in the coaxial cable that is connected to the 935–940 FORWARD RF
IN port at the HU.
11. Subtract the value of the external attenuators from the total composite signal power (P
tot
)
and record the result. This value will be required when setting the attenuation of the HU’s
internal forward path attenuators.
2.4 Enter Site Name and Site Number
All HU’s and RU’s are programmed with the same site name and site number. It is therefore
necessary to assign a unique site name and site number to the HU and RU before they can be
connected to the same CAN network. Use the following procedure to assign a unique site name
and number to each HU and RU system:
1. Click on the HOST Config tab and on the REMOTE Config tab. The HOST Config
display and the REMOTE Config display will open within the EMS main window as
shown in Figure 3-6.
Figure 3-6. HOST and REMOTE Config Displays
Caution: The Host Unit can be damaged if it is overdriven by the EBTS. Always install an
external protective attenuator at the Host Unit FWD RF IN port if the forward path composite
input signal level is greater than –12 dBm.
HOST Site Number
HOST Site Name
REMOTE Site Number
(Entered automatically
when the HOST site
number is selected)
REMOTE Site Name
Click on the Edit button
to open pop-up screen