2.1 Turn-Up Procedure
Each Digivance system must be turned-up separately before being networked together with
multiple systems through the CAN interface. Use the following procedure to turn-up each
Digivance system:
1. Temporarily disconnect the external alarm system or notify the alarm system provider that
testing is in progress.
2. If the HU is networked together with multiple HU’s, temporarily disconnect the CAN cables
from the NET IN and NET OUT ports of the HU.
3. Determine if the forward path composite input signal level at each host unit RF IN port
(851–869 FORWARD and 935–940 FORWARD) is appropriate to produce the required
RF output signal level. Adjust by installing an external attenuator if necessary. Refer to
Section 2.3 for the calculation and adjustment procedure.
4. Connect the EMS computer (if not already connected) to the SERVICE connector on the
HU or STM front panel. If necessary, a separate laptop computer loaded with EMS Version
3.01 software can be temporarily connected and used to initially configure the system.
5. At the HU: Place the ON/OFF switch on the HU in the ON position (press I).
6. At the RU: Make sure the RF switch on the LPA is in the OFF position. Then place the
ON/OFF switch on the STM in the ON position (press I).
7. Wait 6 to 8 seconds for the HU and the RU modules to initialize and then observe the LED
indicators on the HU, STM and LPA. Refer to Section 4 for the troubleshooting
procedures if the indicators do not respond as specified in Table 3-1.
Table 3-1. LED Indicator Operation at Initial Turn-Up
Note: By default, all HU’s and RU’s are programmed with the same site number and
name. This can cause problems for the EMS if multiple HU’s with the same site number
and site name are networked together through the CAN interface. It is therefore necessary
to temporarily disconnect the CAN interface cables from the HU when it is being
configured for operation until a unique site number and name can be assigned.
HOST UNIT SPECTRUM TRANSPORT MODULE 35 WATT LPA
POWER – Green
AC POWER – Green FAIL – Off
STANDBY – Off STANDBY – Off
SHUTDOWN – Red
HOST UNIT – Green HOST UNIT – Green
Digital Display – FORCED
SHUTDOWN
REMOTE UNIT – Green
STM – Green
DRIVE 851–869 and DRIVE
935–940 – Green, Yellow, or Red
PA – Green
FWD/REV (PORT 1/PORT 2) –
Green
VSWR – Green
FWD/REV (PORT 1/PORT 2) –
Green