User Manual

ADCP-75-159 Issue 1 August 2003 Section 1: Overview
Page 1-3
© 2003, ADC Telecommunications, Inc.
2.2 Enhanced Base Transceiver Station to Host Unit Interface
The HU may be interfaced with one or more EBTS’s. Each EBTS provides the RF channel
inputs and outputs for a designated sector. Interfacing the HU with multiple EBTS’s will
generally require installation of the SMR Interface Panels which are accessory products for the
Digivance system.
Two types of Interface Panels are available: the Primary Interface Panel and the Expansion Panel.
The Primary Interface Panel provides attenuation of the forward path signal to the level required
for input to the Host Unit. The Primary Interface Panel also provides forward and reverse path
combining and splitting to permit up to 6 EBTS’s to be connected to a single Host Unit. A typical
Primary Interface Panel configuration with multiple EBTS’s connected to a single Host Unit is
shown in Figure 1-2.
Figure 1-2. EBTS/HU Interface with Primary Interface Panel
The Expansion Panel is used in conjunction with the Primary Interface Panel when the Host
Unit must be interfaced with more than six EBTS’s. Each Primary Interface Panel can support
two Expansion Panels and each Expansion Panel can support up to six EBTS’s. When
configured as shown in Figure 1-3, a total of eighteen EBTS’s can be interfaced with one Host
Unit.
18820-A
HOST UNIT
3 x 1
3 x 1
ENHAN. BASE
TRANSCEIVER
STATIONS
ENHAN. BASE
TRANSCEIVER
STATIONS
PRIMARY
INTERFACE
PANEL
RF
RF
RF
FILTER
FILTER