FCC ID: F8I-DLCSMR2A User Manual - Part 1 ADCP-75-159 Issue 1 August 2003 Digivance® SMR 20 Watt System with Version 2.00.
ADCP-75-159 Issue 1 August 2003 Digivance® SMR 20 Watt System with Version 2.00.
ADCP-75-159 • Issue 1 • August 2003 • Preface COPYRIGHT © 2003, ADC Telecommunications, Inc. All Rights Reserved Printed in the U.S.A. REVISION HISTORY ISSUE DATE 1 08/2003 REASON FOR CHANGE Original issue. TRADEMARK INFORMATION ADC, Digivance, and PowerWorx are registered trademarks of ADC Telecommunications, Inc. Procomm Plus is a registered trademark of Quarterdeck Corporation. DISCLAIMER OF LIABILITY Contents herein are current as of the date of publication.
ADCP-75-159 • Issue 1 • August 2003 • Preface TABLE OF CONTENTS Content Page ABOUT THIS MANUAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii RELATED PUBLICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii ADMONISHMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ADCP-75-159 • Issue 1 • August 2003 • Preface TABLE OF CONTENTS Content 4 5 Page 3.1 Primary Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9 3.2 Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9 3.3 STM and LPA Module Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ADCP-75-159 • Issue 1 • August 2003 • Preface TABLE OF CONTENTS Content 11 Page 10.3 NOC Interface Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-26 10.4 EMS Software User Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-26 SPECIFICATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ADCP-75-159 • Issue 1 • August 2003 • Preface TABLE OF CONTENTS Content Page SECTION 5: MAINTENANCE 1 SYSTEM MAINTENANCE OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1 2 FAULT DETECTION AND ALARM REPORTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2 3 FAULT ISOLATION AND TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ADCP-75-159 • Issue 1 • August 2003 • Preface ABOUT THIS MANUAL This installation and operation manual provides the following information: • An overview of the Digivance SMR 20 Watt System. • A description of the basic system components including the Host Unit (HU), Spectrum Transport Module (STM), Linear Power Amplifier (LPA), Remote Unit (RU) outdoor cabinet, RU indoor mounting shelf, and Digivance Element Management System (EMS). • Installation procedures for the HU.
ADCP-75-159 • Issue 1 • August 2003 • Preface Digivance RF Transport Solution 800 and 1900 MHz Interface Panels User Manual Describes the 800 and 1900 MHz Conditioning Panel and Duplexing Panel and provides procedures for configuration and installation. Digivance System Coarse Wavelength Division Multiplexer User Manual Describes the Coarse Wavelength Division Multiplexer and provides procedures for configuration and installation.
ADCP-75-159 • Issue 1 • August 2003 • Preface Warning: The HU is powered by 48 VDC power which is supplied over customer-provided wiring. To prevent electrical shock when installing or modifying the HU power wiring, disconnect the wiring at the power source before working with uninsulated wires or terminals. Caution: Always allow sufficient fiber length to permit routing of patch cords and pigtails without severe bends.
ADCP-75-159 • Issue 1 • August 2003 • Preface EMS ESD F FCC FDA FSO Fwd GFCI GUI HU IC LED LPA MHz MPE MTBF NC NEM NO NOC NPT OSP PA PC PCS Prg Pwr Rev RF RMA RU RX SMR STM TX UL VAC VDC VSWR WECO WDM Page x © 2003, ADC Telecommunications, Inc.
ADCP-75-159 • Issue 1 • August 2003 • Section 1: Overview SECTION 1: OVERVIEW 1 INTRODUCTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1 2 SMR 20 WATT SYSTEM OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1 3 2.1 Basic System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ADCP-75-159 • Issue 1 • August 2003 • Section 1: Overview with the EBTS), network cables (for connecting multiple HU’s together), and an EMS cable (for connecting the EMS computer to the HU). BASE STATION ANTENNAS HOST UNIT WDM REMOTE UNIT CWDM CWDM REMOTE UNIT CWDM CWDM REMOTE UNIT WDM ENHAN.
ADCP-75-159 • Issue 1 • August 2003 • Section 1: Overview 2.2 Enhanced Base Transceiver Station to Host Unit Interface The HU may be interfaced with one or more EBTS’s. Each EBTS provides the RF channel inputs and outputs for a designated sector. Interfacing the HU with multiple EBTS’s will generally require installation of the SMR Interface Panels which are accessory products for the Digivance system. Two types of Interface Panels are available: the Primary Interface Panel and the Expansion Panel.
ADCP-75-159 • Issue 1 • August 2003 • Section 1: Overview ENHAN. BASE TRANSCEIVER STATIONS ENHAN. BASE TRANSCEIVER STATIONS RF RF 3x1 EXPANSION PANEL RF 3x1 RF ENHAN. BASE TRANSCEIVER STATIONS RF HOST UNIT 3x1 RF 3x1 PRIMARY INTERFACE PANEL FILTER FILTER RF 18821-A ENHAN. BASE TRANSCEIVER STATIONS EXPANSION PANEL 3x1 RF ENHAN. BASE TRANSCEIVER STATIONS RF 3x1 RF ENHAN. BASE TRANSCEIVER STATIONS Figure 1-3. EBTS/HU Interface With Primary Interface Panel and Expansion Panels 2.
ADCP-75-159 • Issue 1 • August 2003 • Section 1: Overview 2.4 Local Service Interface Local communications with an individual Digivance system is supported through a local service interface capability as shown in Figure 4. The primary component of the local interface is a PCtype laptop computer loaded with the Digivance Element Management System (EMS) software. The EMS provides the various control and monitoring functions required for local management of each Digivance system.
ADCP-75-159 • Issue 1 • August 2003 • Section 1: Overview At the NOC, control and monitoring of the networked Digivance systems are effected through a Network Element Manager (NEM) interface which requires only a VT100 terminal/emulator for operation. The NEM interface language consists of simple ASCII text strings. All communications are input as either SET or GET commands which result in ASCII text string responses from the specified system or systems.
ADCP-75-159 • Issue 1 • August 2003 • Section 1: Overview signal is digital, the input and output RF signal levels at the HU or the RU are not dependent on the level of the optical signal or the length of the optical fiber. A diagram of the fiber optic transport system for a typical Digivance system is shown in Figure 1-6. The Digivance 20 Watt system does not support reverse path diversity at this time.
ADCP-75-159 • Issue 1 • August 2003 • Section 1: Overview FIBER OPTIC LINK HOST UNIT 1 CWDM A CWDM A REMOTE UNIT 1 CWDM B CWDM B REMOTE UNIT 2 CWDM C CWDM C REMOTE UNIT 3 CWDM D CWDM D REMOTE UNIT 4 HOST UNIT 2 FORWARD AND REVERSE PATH HOST UNIT 3 HOST UNIT 4 18528-A Figure 1-8.
ADCP-75-159 • Issue 1 • August 2003 • Section 1: Overview The EMS software is used to provision and configure the Digivance system for operation. This includes selecting a sitename, setting alarm thresholds, and setting forward and reverse path RF gain adjustments. The EMS software is also used to get alarm messages (individual or summary), data measurements, or to upgrade the HU/RU system software.
ADCP-75-159 • Issue 1 • August 2003 • Section 1: Overview The indoor RU is designed for mounting in a non-condensing indoor environment such as inside a wiring closet or within an environmentally-controlled cabinet. The indoor RU is intended for rack-mount applications and may be mounted in either a 19- or 23-inch WECO or EIA equipment rack. The indoor RU consists of a Spectrum Transport Module (STM), a Linear Power Amplifier (LPA) module, and a mounting shelf that supports the modular components.
ADCP-75-159 • Issue 1 • August 2003 • Section 2: Description SECTION 2: DESCRIPTION Content Page 1 INTRODUCTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3 2 HOST UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3 2.1 Primary Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ADCP-75-159 • Issue 1 • August 2003 • Section 2: Description 5.10 User Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-17 6 LINEAR POWER AMPLIFIER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-19 6.1 Primary Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ADCP-75-159 • Issue 1 • August 2003 • Section 2: Description 1 INTRODUCTION This section describes the basic components of the Digivance SMR 20 Watt system including the Host Unit (HU), the Remote Unit (RU), and the Digivance Element Management System (EMS). Also described are various accessory items including the Interface Panels, Wavelength Division Multiplexer (WDM) system, and Coarse Wavelength Division Multiplexer (CWDM) system.
ADCP-75-159 • Issue 1 • August 2003 • Section 2: Description 17.1 INCHES (433 mm) FRONT PANEL MOUNTING BRACKET (BOTH SIDES) 3.5 INCHES (88 mm) 12.2 INCHES (311 mm) 17857-A Figure 2-1. Host Unit 2.3 Fault Detection and Alarm Reporting The HU detects and reports various faults including host unit fault, optical fault, power fault, temperature fault, and RF fault. Various front panel Light Emitting Diode (LED) indicators turn from green to red or yellow if a fault is detected.
ADCP-75-159 • Issue 1 • August 2003 • Section 2: Description The host forward path attenuator adjusts the level of the input RF signal to the HU. Using the forward path attenuator, an input signal with a nominal composite signal level of –20 dBm to –40 dBm can be adjusted to produce maximum power output. Additional external attenuation is required if the input signal level is greater than –20 dBm.
ADCP-75-159 • Issue 1 • August 2003 • Section 2: Description 2.11 Cooling Continuous airflow for cooling is provided by dual fans mounted on the right side of the HU housing. A minimum of 3 inches (76 mm) of clearance space must be provided on both the left and right sides of the HU for air intake and exhaust. An alarm is provided if a high temperature condition (>50º C/122º F) occurs. The fans may be field-replaced if either fan fails. 2.
ADCP-75-159 • Issue 1 • August 2003 • Section 2: Description Table 2-1. Host Unit User Interface REF NO USER INTERFACE DESIGNATION DEVICE FUNCTIONAL DESCRIPTION 1 I/0 On/Off rocker switch Provides DC power on/off control. 2 POWER Multi-colored LED (green/yellow) Indicates if the HU is powered (green) or unpowered (off). See Note.
ADCP-75-159 • Issue 1 • August 2003 • Section 2: Description 3 REMOTE UNIT OUTDOOR CABINET The RU cabinet, shown in Figure 2-3, is a NEMA-3R enclosure (with removable dust filter) that provides the following basic functions: • Houses the various electronic modules (STM and LPA) and accessories (WDM or CWDM) and protects them from the weather. • Provides electrical interface connections for the STM and LPA modules. • Provides ventilation openings to allow for entry of cool air and the escape of heated air.
ADCP-75-159 • Issue 1 • August 2003 • Section 2: Description 3.1 Primary Components The RU outdoor cabinet consists of the enclosure, mounting slots for the STM and LPA modules, connectors and a wiring harness for interfacing the STM and LPA modules, a mounting slot for either the WDM or CWDM module (accessory items), lightning protector, and two fiber storage spools. The RU outdoor cabinet is designed for use in an outdoor environment.
ADCP-75-159 • Issue 1 • August 2003 • Section 2: Description 3.5 Fiber Optic Cable Entry A plastic cord connector is provided in the exterior bottom side of the RU cabinet for routing a fiber optic cable into the enclosure. The cord connector provides cable strain relief and a watertight seal at the fiber optic cable entry point. As the connector nut is tightened, a soft neoprene bushing compresses to tightly grip the cable without applying excessive force to the fibers.
ADCP-75-159 • Issue 1 • August 2003 • Section 2: Description 3.8 Ventilation Vent openings are provided in the bottom of the RU cabinet to permit air exchange for cooling. Air enters the cabinet through an opening in the front/bottom side of the cabinet A Filter removes dirt particles so that only clean air enters the enclosure. Both the STM and LPA have cooling fans. The STM has a rear mounted fan that pulls air through the module and exhausts it toward the rear of the enclosure.
ADCP-75-159 • Issue 1 • August 2003 • Section 2: Description (7) CWDM POWER CORD (6) WDM/CWDM MOUNTING SLOT (3) DOOR SWITCH (5) STM MOUNTING SLOT (4) LPA MOUNTING SLOT (9) LIGHTNING PROTECTOR (2) AC POWER CABLE (8) FIBER SLACK SPOOLS BOTTOM VIEW OF CABINET (10) FIBER CABLE CONNECTOR (1) AIR INLET FILTER (12) GROUNDING LUG (11) 3/4-INCH NPT THREADED HOLE Figure 2-4. Remote Unit Outdoor Cabinet User Interface Page 2-12 © 2003, ADC Telecommunications, Inc.
ADCP-75-159 • Issue 1 • August 2003 • Section 2: Description 4 REMOTE UNIT INDOOR MOUNTING SHELF The RU indoor mounting shelf, shown in Figure 2-5, is a rack-mountable framework that provides the following basic functions: • Supports the various electronic modules (STM and LPA) and accessories (WDM or CWDM) for mounting within a standard 19-inch, WECO or EIA, equipment rack. • Provides the electrical interface connections for the STM and LPA modules.
ADCP-75-159 • Issue 1 • August 2003 • Section 2: Description 4.2 STM and LPA Module Installation Two mounting slots are provided within the indoor mounting shelf for installing the STM and LPA modules. The mounting slots include tracks that guide each module into the installed position. Separate mounting slots are provided for STM and LPA modules. Two D-sub connectors (one male, one female) are located at the rear of each mounting slot.
ADCP-75-159 • Issue 1 • August 2003 • Section 2: Description (7) CWDM DC POWER CABLE (6) CWDM MOUNTING SLOT (5) WDM MOUNTING SLOT 18642-A (4) AC POWER CABLE (3) GROUNDING STUDS (INSIDE) (2) LPA MOUNTING SLOT (1) STM MOUNTING SLOT Figure 2-6. Remote Unit Indoor Mounting Shelf User Interface Table 2-3. Remote Unit Outdoor Mounting Shelf User Interface REF NO 5 DEVICE FUNCTIONAL DESCRIPTION 1 STM mounting slot Provides a mounting point for the STM module.