ADCP-75-126 • Issue B • April 2002 • Section 3: Host Unit Installation
Page 3-3
©
2002,
ADC
Telecommunications,
Inc.
Figure 3-1. Typical OSP Cable Routing
At
the
RU,
the
OSP
fiber
optic
cable
should
be
spliced
to
a
connectorized
outdoor-rated
cable
(consisting
of
individual
jacketed
pigtails)
which
is
routed
into
the
RU
cabinet.
The
individual
pigtails
can
then
be
connected
directly
to
the
STM
optical
ports.
A
connector
is
provided
on
the
bottom
of
the
RU
cabinet
to
seal
the
cable
entry
point
and
provide
strain
relief.
The
procedure
for
routing
the
fiber
cable
into
the
RU
cabinet
and
for
connecting
the
pigtail
leads
to
the
STM
is
provided
in
the
Digivance
LRCS
Single
Band
SMR
Remote
Unit
Installation
Instructions
(ADCP-75-122).
When
all
splices
and
terminations
are
completed,
test
each
fiber
for
optical
loss
as
described
in
Section
5
of
this
document.
The
optical
loss
budget
for
9/125,
single-mode
fiber
is
25
dB
minimum
for
an
optical
BER
of
10
-6
.
The
power
level
of
the
received
optical
signal
should
not
exceed
–15
dBm
to
avoid
overdriving
the
optical
receiver.
If
necessary,
use
an
in-line
optical
attenuator
to
adjust
the
signal
level.
HOST UNIT
FIBER DISTRIBUTION PANEL
X
X
STM
REMOTE SITE
HOST SITE
PATCH
CORD
SPLICE
PIGTAIL
SPLICE
ENCLOSURE
INDOOR/OUTDOOR
CABLE WITH
PIGTAIL LEADS
OUTSIDE PLANT
CABLE
REMOTE UNIT
CABINET
16889-A