User Manual

ADCP-75-126 Issue B April 2002 Section 5: Maintenance
Page 5-17
©
2002,
ADC
Telecommunications,
Inc.
12. Place
the
HU
On/Off
switch
in
the
ON
position
(press
I).
13. Verify
that
the
fans
run
properly
following
power-up.
14. Notify
the
NOC
or
alarm
monitoring
system
operator
that
the
system
is
going
back
online.
5.4 Spectrum Transport Module Fan Replacement Procedure
The
STM
is
equipped
with
a
rear
cooling
fan
that
exhausts
heated
air
from
the
STM
enclosure.
Cool
air
enters
the
STM
through
vent
openings
on
the
side
of
the
enclosure.
Replacement
of
the
fan
requires
that
the
STM
be
turned
off
for
a
short
period
of
time
and
that
the
STM
be
removed
from
the
cabinet.
Use
the
following
procedure
to
remove
and
replace
the
STM
cooling
fan.
1. Before
working
on
the
STM
or
handling
a
fan,
slip
on
an
Electro-Static
Discharge
(ESD)
wrist
strap
and
connect
the
ground
wire
to
an
earth
ground
source.
Wear
the
ESD
wrist
strap
while
completing
each
section
of
the
fan
installation
procedure.
2. Notify
the
NOC
or
alarm
monitoring
system
operator
that
the
system
is
going
offline.
3. Place
the
STM
On/Off
switch
in
the
OFF
position
(press
O).
4. Disconnect
the
various
power,
fiber
optic,
service,
alarm
wiring,
and
coaxial
cable
connectors
from
the
STM
front
panel
as
specified
in
Figure 5-4.
Figure 5-4. Spectrum Transport Module Cable Connections
Warning:
Electronic
components
can
be
damaged
by
static
electrical
discharge.
To
prevent
ESD
damage,
always
wear
an
ESD
wrist
strap
when
working
on
the
HU,
STM,
or
LPA
and
when
handling
electronic
components.
17550-A
Disconnect AC
power connector
Disconnect back-up battery
DC power connector
Disconnect alarm
connector
Disconnect diversity
antenna connector
(if present)
Disconnect antenna
connector
1
2
3
4
5
6
7
Disconnect optical fiber
connectors. Place a dust
cap over each cable
connector and port adapter.
Disconnect service
connector (if present)