User Manual

ADCP-75-126 Issue B April 2002 Section 5: Maintenance
Page 5-9
©
2002,
ADC
Telecommunications,
Inc.
During
normal
STM
operation,
all
LED’s
should
be
green
except
the
STANDBY
LED
which
should
be
Off.
When
a
Minor
alarm
occurs,
one
or
more
of
the
LED’s
will
turn
yellow.
When
a
Major
alarm
occurs,
one
or
more
of
the
LED’s
will
turn
red.
During
normal
LPA
operation,
all
LED’s
should
be
Off.
Table 5-8. STM and LPA Fault Isolation and Troubleshooting
Alarm Type LED Color
Minor STM Yellow
PROBLEM: The STM is overheating.
POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS
1.
Air
intake
or
exhaust
opening
to
the
remote
unit
cabinet
is
blocked
2.
Ambient
temperature
>
50º
C/122º
F.
3.
Faulty
fan.
1.
Remove
cause
of
air-flow
blockage.
2.
Reduce
ambient
temperature.
3.
Replace
STM
fan
(See
Section
5.4).
Alarm Type LED Color
Minor HOST UNIT Yellow
Problem: A minor alarm is detected at the HU.
POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS
1.
The
HU
is
overheating.
1.
Check
HU
for
alarms
and
refer
to
Table 5-7
Alarm Type LED Color
Minor PA Yellow
PROBLEM: The LPA is overheating.
POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS
1.
Air
intake
or
exhaust
opening
to
the
remote
unit
cabinet
is
blocked
2.
Ambient
temperature
>
50º
C/122º
F.
3.
Faulty
fan.
1.
Remove
cause
of
air-flow
blockage.
2.
Reduce
ambient
temperature.
3.
Replace
LPA
fan
(See
Section
5.5).
Alarm Type LED Color
Major AC POWER Red
PROBLEM: The RU is powered by the back-up battery system
POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS
1.
The
AC
power
system
circuit
breaker
is
open
or
the
AC
power
has
failed.
1.
Check
the
AC
power
system,
repair
as
needed,
and
reset
circuit
breaker.
Alarm Type LED Color
Major HOST UNIT Red
PROBLEM: A major alarm is detected at the HU.
POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS
1.
The
HU
has
failed.
1.
Check
HU
for
alarms
and
refer
to
Table 5-7.