ADCP-75-158 • Preliminary Issue A • June 2003 • Section 3: Host Unit Installation
Page 3-11
© 2003, ADC Telecommunications, Inc.
Figure 3-9. Fiber Optic Cable Connections To Host Unit
7. At the fiber distribution panel, identify the OSP optical fiber terminations that correspond
to the forward and reverse path.
8. Remove the dust caps from the from the patch cord connectors.
9. Clean each patch cord connector (follow patch cord supplier’s recommendations) and then
mate the connector with the appropriate OSP optical fiber termination.
10. Store any excess patch cord slack at the fiber distribution panel.
7.2 Optical Connections With WDM System
Use the following procedure to connect the optical fibers when a WDM module is installed with
the HU:
1. Obtain a patch cord that is of sufficient length to reach from the WDM host module to the
fiber distribution panel.
2. Remove the dust cap from Port 1 or Port 4 on the WDM module and from the patch cord
connector that will be connected to the WDM module.
Note: Each WDM module can support two separate HU’s. The WDM module ports are
numbered from 1 through 6 as shown in Figure 3-10. Ports 1 through 3 are used for HU #1
and Ports 4 through 6 are used for HU #2.
18656-A
PORT 1
(FORWARD PATH)
PORT 2
(REVERSE PATH)