User Manual

ADCP-75-158 Preliminary Issue A June 2003 Section 4: Operation
Page 4-3
© 2003, ADC Telecommunications, Inc.
2.1 Turn-Up Procedure
Each Digivance system should be turned-up separately before being networked together with
multiple systems through the CAN interface. Use the following procedure to turn-up each
Digivance system:
1. Temporarily disconnect the external alarm system or notify the alarm system provider that
testing is in progress.
2. If the HU is networked together with multiple HU’s, temporarily disconnect the CAN cables
from the NET IN and NET OUT ports of each HU.
3. Determine if the forward path composite input signal level at the Host Unit FORWARD RF IN
port is appropriate for the required RF output signal level and adjust by installing an external
attenuator if necessary. Refer to Section 2.3 for the calculation and adjustment procedure.
4. Connect the EMS computer (if not already connected) to the SERVICE connector on the
HU or STM front panel. If necessary, a separate laptop computer loaded with the EMS
Version 2.0 software can be temporarily connected and used to initially configure the
system.
5. Place the ON/OFF switch on the HU in the ON position (press I).
6. Make sure the switch on the LPA is in the MUTE position and then place the ON/OFF
switch on the STM in the ON position (press I).
7. Wait 6 to 8 seconds for the HU and the RU modules to initialize and then observe the LED
indicators on the HU, STM and LPA. Refer to Section 5 for the troubleshooting
procedures if the indicators do not respond as specified.
8. Start up the EMS Version 2.0 software program. The EMS main window will open as
shown in Figure 4-1. Note: The EMS software should be installed on a PC-type computer
and the PC’s COM port should be configured to interface with the HU. For information
about installing the EMS software and configuring the PC’s COM port, refer to the
Digivance Element Management System Software User Manual (ADCP-75-125).
Note: By default, all HU’s and RU’s are programmed with the same site number and
name. This can cause problems for the EMS if multiple HU’s with the same site number
and site name are networked together through the CAN interface. It is therefore necessary
to temporarily disconnect the CAN interface cables from the HU when configuring the
system for operation until a unique site number and name can be assigned.
HOST UNIT SPECTRUM TRANSPORT MODULE LINEAR POWER AMPLIFIER
POWER – Green
AC POWER – Green STATUS – Steady green
STANDBY – Off STANDBY – Off
HOST UNIT – Green HOST UNIT – Green
REMOTE UNIT – Green
STM – Green
DRIVE – Green, Yellow, or Red PA – Green
PORT 1/PORT 2 – Green VSWR – Green
PORT 1/PORT 2 – Green