User Manual

ADCP-75-158 Preliminary Issue A June 2003 Section 2: Description
Page 2-12
© 2003, ADC Telecommunications, Inc.
4 REMOTE UNIT INDOOR MOUNTING SHELF
The RU indoor mounting shelf, shown in Figure 2-5, is a rack-mountable framework that
provides the following basic functions:
Supports the various electronic modules (STM and LPA) and accessories (WDM or
CWDM) for mounting within a standard 19-inch, WECO or EIA, equipment rack.
Provides the electrical interface connections for the STM and LPA modules.
Provides an AC power cord for powering the STM module
Provides DC power connections for the CWDM module.
4.1 Primary Components
The RU indoor mounting shelf is a rack-mountable frame assembly that provides mounting
slots for the STM, LPA, WDM (accessory), and CWDM (accessory) modules plus connectors
and a wiring harness for interfacing the STM and LPA modules. The indoor mounting shelf is
designed for mounting in a standard 19-inch, EIA or WECO, equipment rack. The frame
assembly is constructed of aluminum and is painted putty white for corrosion protection.
Table 2-2. Remote Unit Cabinet User Interface
REF
NO
DEVICE FUNCTIONAL DESCRIPTION
1 Air inlet filter Reusable filter that prevents the entry of dirt particles when out-
side air is pulled into the cabinet for cooling.
2 AC power cord Provides AC power to the STM.
3 Door switch Indicates to the fault detection and alarm reporting system if the
cabinet door is open (major alarm) or closed.
4 LPA mounting slot Provides a mounting point for the LPA module.
5 STM mounting slot Provides a mounting point for the STM module.
6 WDM/CWDM mounting
slot
Provides a mounting point for either the WDM or CWDM mod-
ule.
7 CWDM power cord Provides DC power to the CWDM module.
8 Fiber slack spools Provide a storage place for excess fiber pigtail and patch cord
slack.
9 Lightning protector Provides lightning surge protection for the antenna connection.
10 Fiber cable connector Provides both an entry point and strain relief for the fiber optic
cable.
11 3/4-inch NPT threaded hole Provides a connection point for a 3/4-inch AC conduit fitting.
12 Grounding lug Provides a connection point for an external grounding cable.