ADCP-75-150 • Preliminary Issue A • March 2003 • Section 5: Maintenance
Page 5-8
©
2003,
ADC
Telecommunications,
Inc.
During
normal
STM
operation,
all
LED’s
should
be
green
except
the
STANDBY
LED
which
should
be
Off.
When
a
Minor
alarm
occurs,
one
or
more
of
the
LED’s
will
turn
yellow.
When
a
Major
alarm
occurs,
one
or
more
of
the
LED’s
will
turn
red.
It
is
recommended
that
whenever
there
are
multiple
alarms,
the
optical
alarms
should
be
checked
and
cleared
first.
Because
the
host
and
remote
units
function
as
a
system,
a
fault
in
the
fiber
optic
link
will
cause
various
unit
alarms
to
be
reported.
Table 5-8. STM Fault Isolation and Troubleshooting
LED: AC POWER Color: Off Alarm Type: Major
PROBLEM: The RU is powered by the battery back-up system.
POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS
1.
The
AC
power
system
circuit
breaker
is
open
or
the
AC
power
has
failed.
2.
The
STM
has
failed.
1.
Check
the
AC
power
system,
repair
as
needed,
and
reset
circuit
breaker.
2.
Replace
the
STM.
LED: STANDBY Color: Green (blinking) or
Yellow (blinking)
Alarm Type: None
PROBLEM: The RU is out of service.
POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS
1.
The
RU
is
in
the
standby
(green)
or
program
load
(yellow)
mode.
1.
Use
DEMS
to
place
the
RU
in
the
normal
(off)
mode.
LED: HOST UNIT Color: Yellow Alarm Type: Minor
Problem: A minor alarm fault is detected at the HU.
POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS
1.
The
HU
is
overheating.
1.
Check
HU
LED
indicators
and
refer
to
Table 5-7
LED: HOST UNIT Color: Red Alarm Type: Major
PROBLEM: A major alarm fault is detected at the HU.
POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS
1.
Fiber
optic
link
fault.
2.
The
HU
is
not
powered.
3.
The
HU
has
failed.
1.
Check
HU
LED
indicators
and
refer
to
Table 5-7.
2.
Check
HU
LED
indicators
and
refer
to
Table 5-7.
3.
Check
HU
LED
indicators
and
refer
to
Table 5-7.
LED: STM Color: Yellow Alarm: Minor
PROBLEM: The STM is overheating.
POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS
1.
Air
intake
or
exhaust
opening
to
the
remote
unit
cabinet
is
blocked
2.
Ambient
temperature
>>
50º
C/122º
F.
3.
Faulty
fan.
1.
Remove
cause
of
air-flow
blockage.
2.
Reduce
ambient
temperature.
3.
Replace
STM
fan
(See
Section
5.4).