User Manual
ADCP-75-150 • Preliminary Issue A • March 2003 • Section 5: Maintenance
Page 5-7
©
2003,
ADC
Telecommunications,
Inc.
LED: REMOTE UNIT Color: Yellow Alarm Type: Minor
PROBLEM: A minor alarm fault is detected at the RU.
POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS
1.
The
STM
or
LPA
is
overheating.
1.
Check
RU
LED
indicators
and
refer
to
Table 5-8
LED: REMOTE UNIT Color: Red Alarm Type: Major
PROBLEM: A major alarm fault is detected at the RU.
POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS
1.
Fiber
optic
link
fault.
2.
AC
power
failure
at
RU.
3.
High
VSWR.
4.
The
RU
cabinet
door
is
open
or
the
STM
or
LPA
has
failed.
1.
Check
RU
LED
indicators
and
refer
to
Table 5-8.
2.
Check
RU
LED
indicators
and
refer
to
Table 5-8.
3.
Check
RU
LED
indicators
and
refer
to
Table 5-8.
4.
Check
RU
LED
indicators
and
refer
to
Table 5-8.
LED: DRIVE Color: Yellow Alarm Type: Minor
PROBLEM: The RF input signal level is below the underdrive threshold.
POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS
1.
Faulty
BTS
or
faulty
coaxial
connection
between
the
HU
and
the
BTS.
2.
Incorrect
attenuation
in
forward
path
RF
coax-
ial
link.
1.
Check
forward
path
signal
level
at
the
HU.
2.
Check
Host
Forward
Attenuator
setting
and
adjust
if
attenuation
is
too
high.
LED: DRIVE Color: Red Alarm Type: None
PROBLEM: The RF signal is above the overdrive threshold.
POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS
1.
Composite
output
signal
level
from
BTS
is
too
high.
2.
Incorrect
attenuation
in
forward
path
RF
coaxial
link.
1.
Check
BTS
composite
output
signal
level
and
adjust
if
too
high.
2.
Check
Forward
Attenuator
setting
and
adjust
if
attenuation
is
too
low.
LED: PORT 1/PORT 2 Color: Red Alarm Type: Major
PROBLEM: Excessive errors are detected in the reverse path optical signal.
POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS
1.
Faulty
reverse
path
optical
fiber.
2.
Faulty
optical
transmit
port
at
the
STM
or
faulty
optical
receive
port
at
the
HU
1.
Test
optical
fiber.
Clean
connector
if
dirty.
Repair
or
replace
optical
fiber
if
faulty.
(See
Section
4.1).
2.
Test
optical
ports.
Replace
HU
or
STM
if
port
is
faulty
(See
Section
4.2).
Table 5-7. Host Unit Fault Isolation and Troubleshooting, continued