User Manual

ADCP-75-150 Preliminary Issue A March 2003 Section 2: Description
Page 2-31
©
2003,
ADC
Telecommunications,
Inc.
Physical/Environmental/
Electrical - Remote Unit Outdoor
Cabinet
Cabinet
dimensions
(H×W×D) 25.6
× 10.13 × 20.75
inches
(674
×
257
×
527
mm)
Mounting Wall,
pole,
or
pedestal Pedestal
mounting
requires
ped-
estal
mount
kit.
(accessory)
Weight 80
lbs
(36.3
kg) Includes
modules
Weather
resistance NEMA-3R,
removable
dust
filter
Operating
temperature –3
to
50º
C
(–22º
to
122º
F)
Storage
temperature –4
to
70º
C
(–40º
to
158ºF)
Humidity 10%
to
90% No
condensation
External
alarm
connector Screw-type
terminals External
alarm
inputs
AC
power
connection 3/4-
or
1/2-inch
conduit Per
local
code
or
practice.
Antenna
cable
connector N-type
female
Fiber
optic
cable
size
0.375
to
0.875
inch
(10
to
22
mm)
diameter
cable
9/125,
single-mode
Lightning
protection 20
kA
IEC
1000-4-5
8/20
µs
waveform
Service
connector DB-9
female
(on
STM) RS-232
DTE
interface
Power
input 120
or
240
VA C ,
50
or
60
Hz Operation
on
240
Vac
requires
removal
of
the
120
Va c
outlet.
Power
consumption 1200
watts
Current
rating 9
Amps
at
120
Vac
Reliability
at
25ºC MTBF
50,000
hours Excluding
fans
and
air
filter
Physical/Environmental/
Electrical - Remote Unit Indoor
Mounting Shelf
Mounting
Shelf
dimensions
(H×W×D)
14.15
× 17.39 × 15.6
inches
(359
×
442
×
396
mm)
Mounting 19-inch
equipment
rack WECO
or
EIA
Weight 50
lbs.
(22.7
kg) Includes
modules
Operating
temperature –3
to
50º
C
(–22º
to
122º
F)
Storage
temperature –4
to
70º
C
(–40º
to
158ºF)
Humidity 10%
to
90% No
condensation
External
alarm
connector Screw-type
terminals
(
on
STM) External
alarm
inputs
AC
power
connection AC
power
cord
with
standard
3-
prong
120
Vac
plug.
Table 2-6. 800 MHz 20 Watt System Nominal Specifications, continued
PARAMETER SPECIFICATION REMARKS