User Manual

ADCP-75-136 Issue 1 November 2002
Page 3
©
2002,
ADC
Telecommunications,
Inc.
optical
transport
connection.
With
62.5
micron
core
multi-mode
fiber
,
the
optical
path
may
be
up
to
500
meters
in
length.
With
50
micron
core
multi-mode
fiber,
the
optical
path
may
be
up
to
750
meters
in
length.
With
9
micron
core
single-mode
fiber,
the
optical
path
may
be
up
to
10
kilometers
in
length.
Single-
and
multi-mode
fibers
may
be
used
in
the
same
system.
The
optical
fibers
must
be
terminated
with
duplex
LC
connectors
for
connection
with
the
DHU,
DEU’s
and
DRU’s.
1.5 Capacity for Expansion and Extended Runs
The
DEU
enables
6-way
expansion
of
any
optical
port.
This
makes
it
possible
to
add
more
DRU’s
without
having
to
install
additional
DHU’s.
Each
DHU
is
equipped
with
six
optical
ports.
If
more
than
six
DRU’s
are
required
by
the
application,
a
DEU
may
be
connected
to
one
of
the
DHU
optical
ports
which
expands
that
port
to
six
ports.
If
still
more
optical
ports
are
required,
then
a
second
DEU
may
be
connected
to
the
DHU;
or
a
second
DEU
may
be
connected
to
the
first
DEU.
The
ability
to
cascade
DEU’s
in
parallel
or
in
series
provides
unlimited
flexibility.
It
is
physically
possible
to
connect
an
unlimited
number
DRU’s
to
the
DHU
through
the
installation
of
DEU’s.
The
maximum
number
of
DRU’s
that
can
connected
to
the
DHU
is
limited
only
by
the
cumulative
noise
effect
caused
by
antenna
combining.
1.6 Power Requirements
The
DHU
and
DEU
are
each
powered
by
120–240
Vac
(50–60
Hz)
power
which
is
supplied
through
a
standard
three-conductor
AC
power
cord.
The
DRU
is
powered
by
34–48
Vdc
which
is
supplied
by
either
the
DHU,
DEU,
or
an
ac/dc
wall-mount
style
converter.
When
the
DRU
is
powered
by
the
DHU
or
DEU,
the
power
is
fed
through
a
category
3
or
5
cable
terminated
with
male
RJ-45
connectors.
1.7 Fault Detection and Alarm Reporting
LED
indicators
are
provided
on
the
front
panel
of
the
various
units
to
indicate
if
the
system
is
normal
or
if
a
fault
is
detected.
In
addition,
normally
open
and
normally
closed
alarm
contacts
(for
both
major
and
minor
alarms)
are
provided
at
the
DHU
for
connection
to
a
customer
provided
external
alarm
system.
This
could
be
a
local
system
or
automatic
call-out
system.