User Manual

ADCP-75-136 Issue 1 November 2002
Page 28
©
2002,
ADC
Telecommunications,
Inc.
Warning:
Wet
conditions
increase
the
potential
for
receiving
an
electrical
shock
when
installing
or
using
electrically-powered
equipment.
To
prevent
electrical
shock,
never
install
or
use
electrical
equipment
in
a
wet
location
or
during
a
lightning
storm.
Use
the
following
procedure
to
install
the
DHU
in
the
equipment
rack:
1.
The
DHU
is
shipped
with
the
mounting
brackets
installed
for
19-inch
rack
installations.
If
mounting
the
DHU
in
a
19-inch
rack,
proceed
to
step
4.
If
mounting
the
DHU
in
a
23-
inch
rack,
proceed
to
step
2.
2.
Remove
both
mounting
brackets
from
the
DHU
(requires
TORX
screwdriver
with
T20
bit)
3.
Reinstall
both
mounting
brackets
so
the
long
side
of
the
bracket
is
flush
with
the
DHU
front
panel
as
shown
in
Figure
13.
Use
the
screws
removed
in
step
2
to
re-attach
the
brackets
to
the
DHU
enclosure.
4.
Position
the
DHU
in
the
designated
mounting
space
in
the
rack
(per
system
design)
as
shown
in
Figure
14.
17271-A
REMOVE AND REINSTALL MOUNTING
BRACKETS AS SHOWN FOR
INSTALLATION IN 23-INCH RACKS
Figure 13. Installing the Mounting Brackets for 23-Inch Rack Installations
17281-A
Figure 14. DHU Rack Mount Installation