4.5.2 Wall-Mount Installation
The DHU may be mounted from any flat vertical surface. It is recommended that a backer
board such as 3/4-inch plywood be applied over the mounting surface to provide a secure base
for attaching the DHU. Two mounting holes are provided in the cable management tray for
securing the DHU to the mounting surface. The fasteners must be provided by the installer.
Use the following procedure to wall-mount the DHU:
Warning: Wet conditions increase the potential for receiving an electrical shock when
installing or using electrically-powered equipment. To prevent electrical shock, never install
or use electrical equipment in a wet location or during a lightning storm.
1. Obtain the appropriate fasteners (lag bolts, screw anchors, etc.) for securing the DHU to
the mounting surface.
2. Position the DHU on the mounting surface in the specified location (per the system
design) with the front panel facing up as shown in Figure 16.
Note: Provide a minimum of 3 inches (76 mm) of clearance space on both the left and right
sides of the DHU for air intake and exhaust.
17272-A
BACKER BOARD SUCH
AS 3/4-INCH PLYWOOD
Figure 16. DHU Wall-Mount Installation
3. Using the DHU as a template, mark the location of the mounting holes on the mounting
surface.
Note: The mounting holes in the DHU cable management tray are spaced 11-21/32 inches
(296 mm) center to center.