5. Secure the mounting brackets to the rack using the four machine screws provided (use
#12-24 screws or M6 x 10 screws, whichever is appropriate).
Note: Provide a minimum of 3 inches (76 mm) of clearance space on both the left and right
sides of the DHU for air intake and exhaust.
4.4.2 Wall-Mount Installation
The DHU may be mounted from any flat vertical surface. It is recommended that a backer
board such as 3/4-inch plywood be applied over the mounting surface to provide a secure base
for attaching the DHU. Two mounting holes are provided in the cable management tray for
securing the DHU to the mounting surface. The fasteners must be provided by the installer.
Use the following procedure to wall-mount the DHU:
Warning: Wet conditions increase the potential for receiving an electrical shock when
installing or using electrically-powered equipment. To prevent electrical shock, never install
or use electrical equipment in a wet location or during a lightning storm.
1. Obtain the appropriate fasteners (lag bolts, screw anchors, etc.) for securing the DHU to
the mounting surface.
2. Position the DHU on the mounting surface in the specified location (per the system
design) with the front panel facing up as shown in Figure 15.
Note: Provide a minimum of 3 inches (76 mm) of clearance space on both the left and right
sides of the DHU for air intake and exhaust.
17272-A
BACKER BOARD SUCH
AS 3/4-INCH PLYWOOD