User Manual
ADCP-75-192 • Issue D • October 2005 • Section 3: Network and System Installation and Setup
Page 3-27
2005, ADC Telecommunications, Inc.
11.2.5 RucXPaY Connection
transceptRanNodeTable.transceptRanNodeRucXPaYConnection, where X=1-3, Y=1-2
These entries manually record the RF connection path between the RAN UpConverter’s PA
outputs and the antenna. For example, if the PA attached to RUC A1’s “1/3” output is
connected to a PCS quadplexer through the B-band port, then transceptRanNodeTable.
transceptRanNodeRuc1Pa1Connection should be set to “pcsBQuadplexer”. This data is best
gathered at installation time. Repeat for all RUCs and PAs as necessary.
11.2.6 RdcZ Multicoupler Connection
transceptRanNodeTable.transceptRanNodeRdcZMulticouplerConnection, Z=1-5
This feature is no longer supported by the Digivance CXD system. This field defaults to
“unconnected”.
11.2.7 Invalid
transceptRanNodeExtTable.transceptRanNodeExtInvalid
This entry resides in the "expansion" table of the RAN Node MIB. If a node in the network
that is now found to be a Hub node resides in the RAN Node MIB (i.e. was previously resident
in a RAN), the Invalid field in the RAN Node MIB will be set to true. This will alert the NMS
to clear that node entry in the RAN Node MIB.
11.2.8 Clean
transceptRanNodeExtTable.transceptRanNodeExtClean
This entry resides in the expansion MIB table of the RAN Node MIB. The RAN Node MIB
keeps a history of every RAN ever seen by the Hub Master node. At times these entries will
become invalid as CPUs are swapped out, etc. To remove old and unwanted node information
from this MIB, the operator must set the “Clean” value to 1. In a matter of seconds, the old
node information will be removed. No further action is required. Note that if the node is
present and valid, it will re-appear within seconds, even if it is cleared.
11.2.9 RAN Disable
transceptRanNodeDisableTable.transceptRanNodeDisableRanState
This entry in the RAN Node MIB allows a given RAN to have all of its PA’s disabled. By
setting this field to "disabled", the Digivance CXD software will automatically push the value
down to the Network Node MIB on the RAN in question, which will cause all PA’s to be
turned off. If this value is set to "enabled", then the RAN Disable states that are maintained on
a per-tenant basis in the Tenant OAM MIB will be used instead.
*Note: This overrides the tenant OAM MIB setting.